Cloud and Pour Point Apparatus Manufacturer,Supplier and Exporter in India
Product Code : EL-OAP-1579
Jlab Export is a leading Cloud and Pour Point Apparatus Manufacturer,and suppliers in India
Cloud and Pour Point Apparatus (code EL-OAP-1579) is a stainless steel cooling bath with a glass test jar, jacket, disc and gasket, built for the IP 15 and IS 1448 (P:10) 1970 methods that find the cloud point and pour point of petroleum oils. Oil and fuel laboratories use the two results to judge how an oil will behave in cold conditions. JLab builds the apparatus in Ambala, India.
Specifications
| Parameter | Detail |
|---|---|
| Built for test methods | IP 15 and IS 1448 (P:10) 1970 |
| Cooling bath | Stainless steel sheet, on a stand with drain plug |
| Bath cover | Thermometer fitting and filling aperture for freezing mixture |
| Supplied with | Glass test jar, jacket, disc and gasket |
| Thermometer IP 1C (extra) | −38 °C to +50 °C |
| Thermometer IP 2C (extra) | −80 °C to +20 °C |
| Quality check | Each apparatus is visually inspected before dispatch |
| Pack quantity | Each (sold individually) |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Product code | EL-OAP-1579 |
| Manufacturer | Jain Laboratory Instruments Pvt Ltd (JLab) — OEM |
| Country of origin | India (made in Ambala, Haryana) |
Reading the Cloud Point and the Pour Point
The cloud point is the temperature at which wax crystals first form a haze in the oil as it cools; the pour point is the lowest temperature at which the oil still flows. For the test, the sample goes into the glass jar, which sits in the jacket on its disc and gasket, and freezing mixture is added to the bath through the filling aperture in the cover. As the oil cools, the jar is checked at intervals: the first haze at the bottom gives the cloud point, and tilting the jar at each check shows the lowest temperature at which the oil still moves.
Thermometers and the Drain Plug
The thermometers are extras. IP 1C reads from −38 °C to +50 °C, and IP 2C goes down to −80 °C for oils that cloud or stop flowing at lower temperatures. After the test, the drain plug on the stand lets the spent freezing mixture run off.
Other Oil Testing Sets in the Range
- Flash Point Pensky Martens Closed — closed-cup flash point tester with electric heater and gas test jet.
- Redwood Viscometer — times oil efflux in Redwood seconds, in two electrically heated models.
- Flash Point — Cleveland open-cup apparatus for the flash and fire points.
Further oil test apparatus sits under Oil and Petroleum, a section of Metallurgical Equipment.
Request a Quote
Order through Add To Cart or write via the contact page, giving the quantity, whether the IP 1C and IP 2C thermometers should be added, and the delivery address.
Last updated: 29 October 2026