This digital ECG takes all 12 leads at the same moment and records them on one or three channels. An LCD shows the operating status and the heart rate. It runs from the mains or from its built-in rechargeable Ni-MH battery, and has an RS 232 port and an interpretive function.

Specifications

RecordingSingle or three channel
AcquisitionSimultaneous 12 lead
Operation modesManual, auto and reference lead
DisplayLCD for operating status and heart rate
InterpretationBuilt-in interpretive function
InterfaceRS 232
PowerAC/DC
BatteryBuilt-in rechargeable Ni-MH
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Lab Exercises in Electrode Placement

Students place all ten electrodes on a Multi Functional Patient Care Nursing Manikin, finding each chest position by counting the rib spaces from the sternal angle. A partner checks every position before the cables go on. They then record once in auto mode and once in manual mode and compare how the leads are laid out.

For a heart rate check on a resting classmate, one student counts beats for a minute with a Stethoscope while another reads the rate on the LCD. Biomedical students also run the unit on battery, note when it asks for charging, and practise cleaning cables and storing the machine.

Frequently Asked Questions

Can the interpretive report be used on its own?
No. The interpretive function adds a computer statement to the record, but the tracing is read by trained staff following the hospital’s own protocol. In training, students compare the statement with their own reading of the trace.

Which chest positions do students most often get wrong?
V1 and V2 are often placed one space too high, and V4 to V6 drift off their lines along the chest wall. Count the rib spaces from the sternal angle every time and place V4 before V3.

Why does the battery run down sooner than it used to?
A Ni-MH battery slowly loses capacity with age and repeated charging. Keep the machine on mains charge between sessions as its manual directs, and replace the pack when the running time no longer covers a ward round or practical.

What is the RS 232 port for?
It is a serial port for linking the machine to a computer or another device, for example to move records off the machine. Many newer computers have no serial port, so a USB to serial adapter may be needed.

Other ECG Machines

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 12 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us