Digital Respirometer Manufacturer,Supplier and Exporter in India

Digital Respirometer

Product Code : EL-DR-2394
Jlab Export is a leading Digital Respirometer Manufacturer,and suppliers in India

A manometric respirometer measures the oxygen uptake of tissue slices, cell suspensions, seeds or yeast from the pressure fall in a closed flask at a steady temperature. This one has a polished stainless steel tank for 7 manometers a side. Its digital display reads the bath temperature to 0.1 °C, and the manometers oscillate at about 90 rpm.

Specifications

TankPolished stainless steel
Manometer capacity7 manometers a side
Reaction flaskCentre well and side flask, attached to the manometer
Manometer scaleGraduated, for reading pressure changes
ShakingManometers oscillate at about 90 rpm
Temperature range5 °C above ambient to 60 °C
Temperature displayDigital, 0.1 °C resolution
Temperature controlWithin ±0.5 °C
Heating and mixingStainless steel immersion heater and stirrer
BodyPowder-coated exterior on wheels
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Respiration Practicals for College Labs

Biochemistry, physiology and pharmacology students use the respirometer to measure how fast a sample takes up oxygen. A little potassium hydroxide solution, made up from Potassium Hydroxide (Pellets), goes in the centre well to absorb carbon dioxide. The sample sits in the main flask, and a substrate or inhibitor can wait in the side flask until it is tipped in during the run. Readings at fixed intervals are plotted against time.

Running the same sample at several bath settings shows the effect of temperature on respiration rate. Flasks with and without alkali in the centre well also give the carbon dioxide output, and from the pair the respiratory quotient. Teachers often show the idea first with the simpler Respirometer built on two boiling tubes. Tissue results can then be set against whole-body oxygen use measured on the Benedict Roth Recording Spirometer.

Frequently Asked Questions

How many samples can be run at once?
The tank takes 7 manometers a side, each with its own flask. Keep one flask with water or buffer only as a thermobarometer. Its reading corrects the others for small changes in room temperature and air pressure during the run.

Can the bath be run below room temperature?
No. The immersion heater controls the bath from 5 °C above ambient up to 60 °C, and there is no cooling. On a warm day, set the bath a few degrees above the room so the controller can hold it steady.

Why are the manometers shaken during a run?
Shaking at about 90 rpm keeps the liquid in each flask moving. Oxygen then passes quickly from the gas space into the sample and carbon dioxide reaches the alkali, so surface gas exchange does not limit the rate you measure.

How is the manometer read?
Note the fluid level on the graduated scale at each time point. The change since the start, minus the change in the thermobarometer, is the pressure change caused by the sample. A flask constant worked out for each flask converts it to a gas volume.

What do students most often get wrong?
Starting readings before the flasks have reached bath temperature, leaving a joint unsealed, and forgetting the thermobarometer correction. Let the flasks settle in the bath first, check every joint for leaks, then read all manometers at the same fixed intervals.