Discharge Over Notches Manufacturer,Supplier and Exporter in India
Product Code : EL-DON-7397
Jlab Export is a leading Discharge Over Notches Manufacturer,and suppliers in India
Discharge Over Notches (code EL-DON-7397) is a self-contained flow-channel rig for calibrating a rectangular notch and 60° and 45° V-notches against a measured flow. Water rises into the channel from below, passes over the notch fitted at one end and is collected in a measuring tank, while a pointer gauge with vernier scale reads the head. JLab builds this three-notch channel in Ambala, India.
Specifications
| Parameter | Detail |
|---|---|
| Notches | Rectangular notch, 60° V-notch and 45° V-notch (interchangeable) |
| Flow channel | Water fed from the bottom; notch fitted at one end |
| Head measurement | Pointer gauge with vernier scale |
| Flow measurement | Measuring tank and stopwatch |
| Water circuit | Self-contained recirculating unit with sump tank and centrifugal pump |
| Flow control | Flow control valve and bypass valve |
| Quality check | Each notch rig is visually inspected before dispatch |
| Pack quantity | Each (sold individually) |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Product code | EL-DON-7397 |
| Manufacturer | Jain Laboratory Instruments Pvt Ltd (JLab) — OEM |
| Country of origin | India (made in Ambala, Haryana) |
Notch Equations Checked on the Channel
For the rectangular notch of crest width b, the discharge is Q = (2/3) Cd b √(2g) H^(3/2); for a V-notch of included angle θ it is Q = (8/15) Cd tan(θ/2) √(2g) H^(5/2), where H is the head above the crest or vertex. Each run takes the actual Q from the measuring tank and stopwatch. The pointer gauge gives H as the difference between the water-surface reading and the crest (or vertex) reading taken with still water standing level with it, so Cd can be worked out at every flow rate.
Comparing the Rectangular and V-Notches
The flow control and bypass valves set a series of flow rates, so Q can be plotted against H for each plate. On log scales the rectangular notch gives a slope near 3/2 and the V-notches a slope near 5/2, and the narrowing V opening keeps the head large enough to read at low flows. At the same head the 60° notch passes more water than the 45° notch, because tan(θ/2) is larger.
Other Notch, Weir and Orifice Rigs
- Notch Apparatus — notch tank with brass trapezoidal and rectangular notches.
- Flow Over Weir or Open Channel Apparatus — interchangeable weirs fitted at the end of a small flow channel.
- Plate Weirs — sharp-crested plate weirs for discharge measurement in open channels.
- Orifice and Mouthpiece Apparatus — constant head rig for orifice and mouthpiece discharge coefficients.
This channel is filed under Discharge Over Notches in the Fluid Mechanics and Hydraulics Lab Equipment section.
Request a Quote
To order, press Add To Cart or write through the contact page with the number of channels required and your delivery town.
Last updated: 30 October 2026