Surgery Microscope Manufacturer,Supplier and Exporter in India
Product Code : EL-MAI-4046
Jlab Export is a leading Surgery Microscope Manufacturer,and suppliers in India
This surgery microscope sends part of its image through a beam splitter to a C-mount digital camera and an LCD monitor fitted on the microscope. A team or a class can then watch the field live. It has a 45° inclined head with 15x wide-field eyepieces and an f = 200 mm objective. Coaxial fibre optic light from twin halogen lamps lights a 70 mm field.
Specifications
| Optical head | 45° inclined |
| Eyepieces | 15x wide field |
| Magnification | 3-step (5x, 10x, 20x), 5-step (0.4x, 0.63x, 1x, 1.6x, 2.5x) or continuous zoom (5x to 25x) |
| Objective | f = 200 mm |
| Interpupillary distance | 55 to 75 mm |
| Focusing | Manual, or motorized with foot control |
| Camera and display | Beam splitter with C-mount CCD digital camera, LCD monitor on the microscope |
| Light | Twin halogen reflector lamps, 15 V/150 W or 24 V/250 W, continuous control |
| Illumination | Coaxial fibre optic light guide through the lens, 70 mm field |
| Filters | Cobalt blue, red-free, heat absorbing |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Training Exercises for Biomedical Engineering Students
Trainees set the interpupillary distance and eyepiece focus, then connect the camera and check that the monitor shows the same field as the eyepieces. They then compare the image on the monitor with the view in the eyepieces.
With a Digital Lux Meter at the 70 mm field, students compare the brightness with and without each filter in place. They check the lamp supply with a Digital Multimeter during a lamp change, and clean the objective with Lens Cleaning Tissue before covering the head.
Frequently Asked Questions
Why is the camera image dark while the eyepiece view is bright?
The beam splitter sends only part of the light to the camera, so the image there is dimmer than in the eyepieces. Check the camera exposure setting, the cable to the monitor and the live view setting on the display before suspecting the camera itself.
What are the cobalt blue, red-free and heat absorbing filters for?
Cobalt blue light makes fluorescein dye glow, and red-free light makes blood vessels stand out dark against the tissue. The heat absorbing filter cuts the heat carried to the field by the halogen light.
How is the interpupillary distance set?
Look through both eyepieces and slide them apart or together until the two circles of light merge into one. The scale covers 55 to 75 mm, and each user can note a personal setting.
What does coaxial illumination do?
The light travels through the lens along the same line as the view. Deep, narrow cavities are then lit to the bottom with almost no shadow, which side lighting cannot do.
When is motorized focus with a foot control useful?
It lets the surgeon refocus without taking the hands off the instruments or touching the microscope. Manual focusing suits simpler setups and teaching labs where the user can reach the knobs.
Other Operation Theatre Equipment
For a quote, use Add To Cart or send us a message through the contact page.