Hand Held Pulse Oximeter Manufacturer,Supplier and Exporter in India
Product Code : EL-PO-3973
Jlab Export is a leading Hand Held Pulse Oximeter Manufacturer,and suppliers in India
Held in one hand and read at a glance, this pulse oximeter gives two values, SpO2 and pulse rate, in bright LED numerals. The user can set the alarm limits freely. It charges from its own seat-type charger, saves power when idle and keeps readings on a built-in memory card for download to a computer.
Specifications
| Parameters | SpO2 and pulse rate |
| Display | Bright LED numerals |
| Alarm | Limits set freely by the user |
| Battery | Built-in rechargeable, with seat-type charger |
| Power saving | Power-saved function |
| Memory | Built-in memory card |
| Data transfer | Connection to a computer for download |
| Build | Light and portable |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Classroom Practicals on Pulse and SpO2
A step test works well with this unit. A student sits quietly while the resting pulse rate and SpO2 are noted, then steps up and down for one minute timed on a Large Display Stopwatch. The group reads the pulse rate every half minute afterwards and plots how it falls back toward rest.
For an alarm exercise, trainees set the pulse rate high limit just below a classmate’s resting value, hear the alarm and then reset it to a sensible level. The class can also download the stored readings and add body temperature taken with a Clinical Thermometer to build a simple observation chart.
Frequently Asked Questions
How is the battery charged?
Stand the oximeter in its seat-type charger whenever it is not in use, for example at the end of a shift or a class. The built-in battery recharges in place, and the power-saved function cuts drain while the unit sits idle.
How do I move stored readings to a computer?
Readings are kept on the built-in memory card. Connect the oximeter to a computer and download the data, then file it or print it as a trend sheet.
Why clear the memory between users?
Stored readings belong to the person they were taken on. After the data has been downloaded, clearing the memory stops one patient’s or student’s readings from mixing with the next set.
What is low perfusion, and why does it give trouble?
Low perfusion means little blood is reaching the probe site, as with cold hands or a weak pulse. The light signal is then small and harder to read. Warm the hand, keep it still or move to another finger.