Pulse Oximeter System Manufacturer,Supplier and Exporter in India

Pulse Oximeter System

Product Code : EL-PO-3971
Jlab Export is a leading Pulse Oximeter System Manufacturer,and suppliers in India

A pulse oximeter shines red and infrared light through a fingertip and works out oxygen saturation (SpO2) and pulse rate from the light that passes through. This bedside system shows both numbers on an LED screen and draws the pleth waveform live on a 3.5 inch LCD. It weighs 1 kg with its battery and stores 72 hours of data for up to 100 patient IDs.

Specifications

ReadingsSpO2 and pulse rate on an LED screen
WaveformReal-time pleth waveform on a 3.5 inch LCD
Weight1 kg with battery
Memory72-hour data storage, 100 patient IDs
Graphs72-hour SpO2 and pulse rate spot graphs
Alarms3-level visual and audio
PowerInternal rechargeable battery for up to 24 hours, or AC mains
Battery lowIndication on the unit
Patient typesAdult, pediatric and neonatal
OptionsBuilt-in thermal recorder, USB data upload
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Lab Exercises in the Nursing Skills Lab

Students take turns as the subject. One clips the probe on a classmate’s finger and waits for the waveform to settle. The classmate then moves the hand, and the group sees how motion breaks up the trace. They repeat it with a cold hand and compare the waveform shape.

For a full set of observations, trainees record SpO2 and pulse rate, then take temperature with a Digital Thermometer and enter the readings under a patient ID. A mock bedside around a Multi Functional Nursing Manikin is used to practise placing the unit, routing the probe cable and setting the alarm levels.

Frequently Asked Questions

What does the pleth waveform tell me?
It traces the pulse beat by beat as the light reaching the sensor rises and falls. A tall, even wave means the probe has a good signal. A flat or ragged wave usually means movement, a loose probe or a cold finger, so check the probe before trusting the numbers.

What are the three alarm levels?
The unit gives visual and audio alarms at three levels, so a more urgent condition looks and sounds different from a minor one. The limits used on patients are set by trained staff in line with the hospital protocol.

Can it be used for babies and children?
It is made for adult, pediatric and neonatal use. Fit a probe sized for the patient, because an adult clip on a small finger lets room light in and gives a weak signal.

How long does it run away from the mains?
The internal rechargeable battery lasts up to 24 hours, and a battery-low indication warns when it needs charging. On AC mains it runs and charges at the same time.

What are the recorder and USB options for?
The optional built-in thermal recorder prints a paper strip of the readings for a file or a teaching folder. The optional USB upload moves stored data to a computer.

Other Pulse Oximeters

For a quote, use Add To Cart or send us a message through the contact page.