Horizontal Cylindrical Sterilizer Manufacturer,Supplier and Exporter in India

Horizontal Cylindrical Sterilizer

Product Code : EL-MS-3762
Jlab Export is a leading Horizontal Cylindrical Sterilizer Manufacturer,and suppliers in India

Loaded from the front through a heavy gun-metal lid, this horizontal sterilizer has a cylindrical stainless steel chamber, 400 x 1200 mm in its common size. It works at 1.26 kgf/cm² and 121 °C on a 240 V single-phase supply. A timer, two pressure gauges, a double safety valve and a water level indicator are fitted.

Specifications

Common size400 x 1200 mm
Chamber and lidStainless steel chamber, heavy gun-metal lid with gasket, radial locking
Steam working pressure1.26 kgf/cm² (2.2 kgf/cm² on the high-speed model)
Steam working temperature121 °C
Sterilization period45–50 minutes
Steam exhaust5–7 minutes
Timer1–60 minutes
Valves and gaugesDouble safety valve, steam release valve, one gauge for the inner chamber and one for the outer chamber
Other fittingsWater level indicator, cold water drainage, heavy-duty plug and socket
Power and spares240 V, single phase, AC, 50 Hz; one spare heating element and two spare gaskets
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Lab Exercises for CSSD Trainees

The long chamber lets trainees practise a lying load. They slide packed drums such as the Sterilizer Shallow Dressing Drum in on their sides with the belts open, leaving space along the chamber wall. Before the run, they read the water level indicator, check that the lid locks evenly and set the timer.

During the run, one student reads the inner chamber gauge and another the outer chamber gauge, and both record the readings at set times. At the end, the class lets the steam out through the release valve, opens the lid once both gauges show zero and unloads onto an Instrument Trolley. Biomedical students can also trace the heater, valves and drain on the unit and fit a spare gasket.

Frequently Asked Questions

Why does it have two pressure gauges?
One gauge reads the pressure inside the chamber where the load sits, and the other reads the outer chamber around it. Watching both lets the operator see that the shell has come up to pressure along with the load space.

What does the 1 to 60 minute timer measure?
It times the hold once the chamber is at working pressure. The whole cycle is longer, because heating up and the 5 to 7 minute steam exhaust come before and after the timed hold.

How much floor space should I plan for?
The common chamber is 400 mm across and 1200 mm long, and the unit stands on the floor with its lid at the front. Leave clear room in front for the lid to swing and for a trolley to come up to the opening.

Which spare parts come with it?
One spare heating element and two spare gaskets come with the unit, along with a heavy-duty plug and socket for the mains connection.

What if the heater stops heating?
Switch off at the socket and let the unit cool fully. A trained technician then checks the element and its connections, and can fit the spare element supplied with the sterilizer if the old one has failed.

Other Hospital Sterilizers

For a quote, use Add To Cart or send us a message through the contact page.