Horizontal Flow from a Tank Manufacturer,Supplier and Exporter in India
Product Code : EL-MLE-13255
Jlab Export is a leading Horizontal Flow from a Tank Manufacturer,and suppliers in India
Horizontal Flow from a Tank (code EL-MLE-13255) is a model JL109/03 set-up for studying the horizontal jet that leaves a tank through an outlet insert and for determining the contraction coefficient of different outlet contours and diameters. A point gauge with eight movable rods traces the jet path against a white panel. JLab manufactures this tank-outlet jet apparatus in Ambala, India.
Specifications
| Parameter | Detail |
|---|---|
| Model | JL109/03 |
| Tank | 510 mm high, 190 mm diameter, about 13.5 L, with adjustable overflow and scale |
| Outlet inserts | Four, interchangeable: rounded contour 4 mm and 8 mm; square contour 4 mm and 8 mm |
| Jet path | Point gauge with 8 movable rods, length 350 mm; white panel for recording the trajectory |
| Flow rate and water supply | Flow rate from the base module; water from the base module or a laboratory supply |
| Accessories | All accessories included |
| Quality check | Each apparatus is visually inspected before dispatch |
| Pack quantity | Each (sold individually) |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Product code | EL-MLE-13255 |
| Manufacturer | Jain Laboratory Instruments Pvt Ltd (JLab) — OEM |
| Country of origin | India (made in Ambala, Haryana) |
From Jet Trajectory to the Contraction Coefficient
With the overflow holding the head h steady, Torricelli’s law gives the ideal outlet velocity v = √(2gh). The jet leaves horizontally and falls under gravity, so a point at horizontal distance x and drop y obeys x² = 4Cv²hy; setting the rods to the jet and reading x and y gives the velocity coefficient Cv. The base module flow rate Q gives the discharge coefficient Cd = Q / (a√(2gh)), where a is the insert area, and the contraction coefficient follows as Cc = Cd / Cv.
Comparing inserts of the same diameter shows the effect of the contour: a rounded entry lets the jet leave nearly full-bore, while a square edge makes it contract to a narrower vena contracta. Comparing the 4 mm and 8 mm inserts of one contour shows the effect of size at the same head.
Other Orifice, Mouthpiece and Bernoulli Apparatus
- Flow Through Orifice and Mouthpiece — coefficients of discharge, velocity and contraction with acrylic orifices and mouthpieces.
- Orifice and Mouthpieces Apparatus — supply tank with a universal fixture for an orifice or mouthpiece.
- Bernoulli’s Principle — Venturi nozzle with tube manometers and a movable Pitot tube.
More flow apparatus is grouped in Mechatronics Lab Equipments, within Mechanical Engineering Lab Equipment.
Request a Quote
Get a quotation for the apparatus with Add To Cart or by writing on the contact page; mention model JL109/03, the number required and the delivery town.
Last updated: 30 October 2026