• +91-85699-09696

Horizontal Laminar Air Flow (Microprocessor Control) Manufacturer,Supplier and Exporter in India

Horizontal Laminar Air Flow (Microprocessor Control)

Product Code : EL-CAB-3825
Jlab Export is a leading Horizontal Laminar Air Flow (Microprocessor Control) Manufacturer,and suppliers in India

This is the microprocessor-controlled version of the horizontal clean bench, for labs that want electronic control of the unit. The filtered stream runs level across a stainless steel table. Its HEPA filter, fed through a pre-filter, retains particles of 0.3 micron and larger. The cabinet comes in four body finishes, including electro galvanized steel.

Technical Details

ControlMicroprocessor control
Air flowHorizontal laminar flow across the work table
FiltrationPre-filter and HEPA filter, 99.99% with cold DOP, 99.97% with hot DOP
Particles retained0.3 micron and larger
Cabinet bodyLaminate-faced wooden board, powder coated cold rolled steel, electro galvanized steel or stainless steel
Working tableStainless steel sheet
Side panels and front doorsThick clear acrylic
Motor and lightingHeavy duty low-noise motor, fluorescent lighting
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Choosing This Model

The filter grade, table, clear acrylic panels, motor and lighting match the standard horizontal cabinet. The differences are the microprocessor control and the wider choice of body: laminate-faced board, powder coated cold rolled steel, electro galvanized steel or stainless steel.

Like every laminar flow clean bench, it protects the work and not the operator. It is not a biosafety cabinet and is not used for infectious material.

Microbiology and Pharmacy Practicals

In a serial dilution practical, students pipette a soil or water sample through a set of dilution tubes inside the bench. They spread each dilution on agar in a Petri Dish (Polypropylene). The plates then go into a BOD Incubator, and colonies are counted later to work out the viable count.

Plant biotechnology students start callus or shoot cultures here and move the vessels to a Plant Growth Chamber or a lit culture rack.

Frequently Asked Questions

How does it differ from the standard horizontal cabinet?
It has microprocessor control, and its body can also be built in electro galvanized steel. The HEPA filter, stainless steel table, clear acrylic panels, motor and fluorescent lighting are the same.

What particle size does the HEPA filter stop?
It retains airborne particles of 0.3 micron and larger. Bacteria and fungal spores fall in that range, which is why the filtered stream keeps open cultures clean.

Can I use an open flame inside the bench?
Keep flames small and brief, or avoid them. A flame heats the air and breaks up the smooth stream, so the area behind it is no longer protected.

Is it used for electronics work as well?
Yes. Besides tissue culture, pharmacy and medical science, the clean air stream suits the inspection and testing of small electronic parts, where dust on a surface spoils the work.

Other Clean Air Benches

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 12 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us