Vertical Laminar Air Flow Cabinet Manufacturer,Supplier and Exporter in India
Product Code : EL-CAB-3801
Jlab Export is a leading Vertical Laminar Air Flow Cabinet Manufacturer,and suppliers in India
In this clean bench the filtered air falls straight down onto the work surface and leaves at the front opening. Room air is drawn through a pre-filter and a HEPA filter, so the falling stream keeps airborne dust and microbes off open plates and cultures. The working table is stainless steel, and the side panels and front door are clear acrylic.
Technical Details
| Air flow | Vertical (downward) laminar flow |
| Cabinet body | Laminate-faced wooden board, cold rolled steel powder coated, or stainless steel (as ordered) |
| Working table | Stainless steel sheet |
| Side panels and front door | Thick clear acrylic |
| Typical uses | Plant tissue culture, pharmacy, medical science, agriculture, electronic parts inspection |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
How Downward Flow Protects the Work
The air moves in one smooth direction, from the top filter to the table, with little mixing. Particles shed near the work are carried down and out instead of drifting across the dishes. The cabinet body can be laminated wooden board, powder coated cold rolled steel or stainless steel, as ordered.
A laminar flow clean bench protects the work, not the user. It is not a biosafety cabinet, so it is not used for infectious material.
Lab Exercises in Sterile Handling
Microbiology students pour sterile nutrient agar into a Petri Dish (Polypropylene) inside the cabinet and let it set with the lid close by. They then streak a culture with an Inoculating Loop Nichrome Wire to get single colonies. The media and glassware are sterilised first in an Autoclave Vertical.
In plant tissue culture classes, students cut surface-sterilised leaf or node pieces on a sterile tile and place them on medium in culture vessels. The downward stream keeps room air off the open vessels while students cut and transfer the pieces.
Frequently Asked Questions
How is vertical flow different from horizontal flow?
Here the air falls from the top onto the table. In a horizontal cabinet it blows from the back wall towards the user. Downward flow sends less filtered air straight at the operator.
Can I handle infectious samples in it?
No. A laminar flow clean bench keeps the work clean but gives the user no protection from what is on the table. Infectious material needs a biosafety cabinet.
Which cabinet material should I order?
Laminated wooden board, powder coated cold rolled steel or stainless steel. The working table is stainless steel in every version, and the sides and door are clear acrylic.
Why keep hands away from the space above open plates?
In downward flow, anything held above an open dish sheds particles that fall straight onto it. Work beside the open plates and keep sleeves and bottles clear of the air path.
How should the bench be prepared before work?
Run the blower for some minutes first, then wipe the table and the inside walls with alcohol. Load only the items you need, so they do not block the air stream.
Other Clean Air Equipment
- Horizontal Laminar Flow Cabinet
- Horizontal Laminar Air Flow (Microprocessor Control)
- Air Curtain
- Tissue Culture Rack
For a quote, use Add To Cart or send us a message through the contact page.