Humidity Oven Manufacturer,Supplier and Exporter in India
Product Code : EL-O-2305
Jlab Export is a leading Humidity Oven Manufacturer,and suppliers in India
A humidity oven is an oven cabinet that also controls the moisture in its air. Heaters dipped in water make steam, the steam condenses in the chamber, and a humidistat holds relative humidity from room level up to 95% RH, within ±3%. It is built in seven chamber sizes, each with two or three trays.
Specifications
| Humidity source | Steam from heaters dipped in water, condensed in the chamber |
| Humidity control | Humidistat, ambient to 95% RH ±3% |
| Chamber sizes (mm) and trays | 300 x 300 x 300 (2), 355 x 355 x 355 (2), 455 x 455 x 455 (2), 455 x 605 x 455 (3), 605 x 605 x 605 (3), 910 x 605 x 455 (3), 910 x 605 x 605 (3) |
| Options | Digital temperature indicator-cum-controller, with or without computer data logger |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Humidity Experiments for Students
A simple practical is moisture uptake. Students dry a hygroscopic salt, spread it in an Evaporating Dish Porcelain and weigh it on an Electronic Balance Analytical. They leave the dish in the oven at a set humidity and weigh it again at fixed times. A plot of mass gained against time shows how fast the salt takes up water.
Teachers can also place a Hygrometer Wet and Dry on a tray. Students read the wet and dry bulbs, find the humidity from a table and compare it with the humidistat setting.
Frequently Asked Questions
Why does the humidity reading change when the temperature changes?
Relative humidity compares the water in the air with the most the air can hold at that temperature. Warm air can hold more water, so the same amount of moisture gives a lower reading when the chamber warms and a higher one when it cools.
Why do droplets form on the walls or on my samples?
Water condenses on any surface colder than the dew point of the chamber air. Samples brought in cold, or a door left open, can cause it. Let samples reach room temperature first and keep door openings short.
How is the humidity made and held?
Heaters sit in a water supply and boil off steam, which condenses into the chamber air. The humidistat senses the humidity and switches the steam heaters on and off to hold the level you set, up to 95% RH.
Which water should be used for the steam heaters?
Distilled or deionised water is the usual choice. Tap water leaves scale on the heaters as it boils away, and scale slows steam output so the chamber takes longer to reach the set humidity.
Other Ovens and Humidity Chambers
- Universal Ovens (same chamber sizes, dry heat only)
- Stability Chamber Microprocessor Control
- Digital Hygrometer with Temperature
For a quote, use Add To Cart or send us a message through the contact page.