Junior Fume Hoods Manufacturer,Supplier and Exporter in India

Junior Fume Hoods

Product Code : EL-LFH-3877
Jlab Export is a leading Junior Fume Hoods Manufacturer,and suppliers in India

The Junior hood is sent flat-packed and put together on site. It comes without a worktop, so it stands on a bench or base cabinet you already have. A counterbalanced tempered glass sash rises vertically at the front, and the front panel carries one water fixture, one gas fixture and two electrical outlets.

Specifications

ConstructionCombined single wall and double wall
SashVertical rising, fail-safe, counterbalanced tempered glass
Cabinet finishAntimicrobial coating
WorktopNone; stands on an existing work surface
DeliveryShipped unassembled, simple assembly on site
Service fixtures1 water fixture, 1 gas fixture and 2 electrical outlets
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

School and College Practicals in the Hood

Salt analysis is the practical that most often sends students to the fume cupboard. Anion tests for sulphide, sulphite and nitrate give off pungent gases. A little of the salt is warmed with acid in a Test Tube Borosilicate Glass. Students do this step under the lowered sash and test the gas at the mouth of the tube.

The gas fixture feeds a Burner Bunsen for heating inside the hood, and the water fixture is used for rinsing and condensers. Before the class, the teacher can tape a tissue strip to the sash edge so students see the air being pulled in.

Frequently Asked Questions

Can our own maintenance staff assemble the hood?
Yes. It is shipped unassembled and goes together by a simple procedure, so a site technician can build it. The exhaust duct, gas line and electrical supply should still be connected by whoever looks after those services in your building.

What should the hood stand on?
It has no worktop of its own, so it sits on a level, chemical-resistant bench top or base cabinet. Check that the surface is big enough for the hood and strong enough to carry it.

Where in the lab should the hood go?
Away from doors, corners, busy walkways and air-conditioning outlets. Air moving across the sash opening can pull fumes out of the hood, so a quiet spot along a side wall works better.

Can more service fixtures be fitted later?
The combined single wall and double wall construction makes it easy to fit service fixtures on the front panel. The standard set is one water fixture, one gas fixture and two electrical outlets.

Should the hood have its own electrical circuit?
It is a good idea. If the hood shares a circuit with the bench sockets, a fault on one socket can trip the supply and stop the extraction. A separate, labelled circuit keeps the hood running.