Kick Bucket Manufacturer,Supplier and Exporter in India

Kick Bucket

Product Code : EL-WF-2009
Jlab Export is a leading Kick Bucket Manufacturer,and suppliers in India

A kick bucket stands on the operating theatre floor to collect used swabs and sponges. Staff push it into place with a foot, so gloved hands never touch it. This one has a stainless steel bowl with a minimum finished thickness of 0.5 mm, held in a steel tubular frame on three swivelling castors.

Specifications

BowlStainless steel
Minimum finished thickness0.5 mm
FrameSteel tubular
CastorsThree, swivelling
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Theatre Practicals with the Kick Bucket

In an operating theatre skills lab, students set up a mock case around a Minor OT Table. The kick bucket goes on the floor at the scrub side, lined with a clear bag, and used practice swabs are dropped into it from the field. Small sharp items are kept apart in a Kidney Tray on the trolley.

Teachers then run a swab count. The circulating student lifts the swabs out with forceps and counts them in batches with the scrub student, and both check the total against the count board before the mock closure.

Frequently Asked Questions

What goes into a kick bucket?
Used swabs, sponges and similar soft items dropped from the operating field. Sharps and instruments do not go in it. They stay on the tray or trolley so they can be counted on their own.

Should the bowl be lined?
Many theatres line it with a clear or plain bag, so swabs can be seen and counted and the bag can be lifted out whole at the end of the case. A coloured bag can hide soaked swabs. Follow the hospital’s own procedure.

Why is it on castors?
So it can be nudged with a foot to wherever the scrub team drops swabs, without anyone touching it with sterile gloves. Three swivelling castors let it turn in any direction in a crowded theatre.

How is it cleaned after a case?
Remove the liner and contents as clinical waste. Wash the stainless steel bowl with detergent, disinfect it as the hospital’s protocol sets, and dry it. Wipe the frame and clear hair or thread from the castors.