Earth Tester (Complete Set) Manufacturer,Supplier and Exporter in India

Image Not Found .

Product Code : EL-LE-11723
Jlab Export is a leading Earth Tester (Complete Set) Manufacturer,and suppliers in India

Earth Tester (Complete Set) (code EL-LE-11723) is a digital earth resistance tester, model JL129/013, that measures earthing resistance on ranges from 0–20 Ω up to 0–4000 Ω by the 2-wire or 3-wire method, and reads AC earth voltage to 400 V on a 4000-count backlit display. Electricians and electrical labs use it to check earth pits, lightning conductors and equipment earthing. JLab builds this tester in Ambala, India.

Specifications

ParameterDetail
ModelJL129/013
Earth resistance ranges0–20, 0–200, 0–2000 Ω and 0–40, 0–400, 0–4000 Ω
AC earth voltage0–400 V
Frequency50 Hz / 60 Hz
Test methodsSimple 2-wire and precise 3-wire
DisplayDigital, 4000 count, backlit LCD 70.6 × 34 mm, over-range indication
MemoryData hold; storage of 20 groups
Power6 × 1.5 V LR6 batteries; auto power-off after about 10 minutes
Size and weight160 × 100 × 70.5 mm, 560 g
ColourRed and grey
Quality checkEach earth tester set is visually inspected before dispatch
Pack quantityEach (sold individually)
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
Product codeEL-LE-11723
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab) — OEM
Country of originIndia (made in Ambala, Haryana)

Two-Wire or Three-Wire Testing

The simple 2-wire method measures between the electrode under test and an existing reference earth, and suits quick routine checks. The precise 3-wire method works with two auxiliary stakes set in a line away from the electrode, which takes lead and contact resistance out of the result and makes it the method for commissioning a new earth pit. Manual ranging holds the meter on one range across a run of pits, and the case has double insulation.

Frequently Asked Questions

Can readings be saved for a report?
Yes. The tester stores 20 groups of data and has data hold, so a series of earth pits can be measured on site and the values written up afterwards.

Why measure the AC earth voltage first?
Stray AC voltage on the earth system, read up to 400 V at 50 Hz or 60 Hz, can disturb the resistance reading, so it should be checked before a resistance test.

Related Electrical Testers

Other testers and meters for electrical work are in Lab Equipment.