Several of these medical syringe pumps can be stacked, one on top of another, so that more than one syringe runs from a compact column at the bedside. Each pump takes power from the mains, its internal battery or a 12 V car supply. A digital LCD shows the working status, and a shuttle knob turns either way to set the parameters.

Technical Details

StackingFreely stackable, one unit on top of another
Power sourcesAC 220 V 50 Hz mains, internal battery, 12 V car supply
DisplayDigital LCD showing the working status
Parameter settingPositive and negative shuttle knob
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Practicals with the Stackable Pump

In a biomedical-engineering lab, a power changeover test comes first. Students run the pump on mains with a water-filled syringe and then pull the plug. It should carry on from the internal battery, and the display should report the change. A battery run-time log follows, with each check timed on a Large Display Stopwatch until the pump stops on battery power.

Students also stack two pumps and mount the column on a Saline Stand, then trace which line belongs to which pump. In a nursing skills lab, the pump stands beside a Multi Functional Nursing Manikin. Trainees practise the start-up checks, reading the LCD and setting values with the shuttle knob.

Frequently Asked Questions

Which power sources can the pump use?
Three: AC 220 V 50 Hz mains, the built-in battery, and a 12 V car supply. The battery keeps it running when it is unplugged to move between rooms, and the car supply is for use in a vehicle.

How should the battery be looked after?
Keep a stored pump on mains so the battery stays charged, and run a short battery-only test at each routine check. Look at the battery contacts during servicing, because corrosion there can stop the unit charging.

Which syringe sizes and brands can be loaded?
Use only the sizes and brands in the pump manual. A syringe pump works out the flow from the barrel diameter. A syringe of another make or size can therefore give a flow that differs from the figure shown.

What does stacking the pumps involve?
One pump sits directly on top of another, and each still runs its own syringe. This saves space on a pole or a shelf when two or more solutions are given together.

How is the shuttle knob used?
Turn it one way to raise a value and the other way to lower it, then confirm the setting. The LCD shows the value as it changes, so the user can watch the figure while turning the knob.