Syringe Pump Dual Channel Manufacturer,Supplier and Exporter in India

Syringe Pump Dual Channel

Product Code : EL-SP-3975
Jlab Export is a leading Syringe Pump Dual Channel Manufacturer,and suppliers in India

A syringe pump pushes the plunger of a loaded syringe forward at a set rate to give a small, steady flow. This dual-channel model holds two syringes and runs each one at its own flow rate. A channel that is not needed can be put to sleep, and the occlusion alarm has three limit levels.

Specifications

ChannelsTwo, each run at its own flow rate
Channel standbyChannel sleeping function
Occlusion alarm3-level limit setting
After an occlusionAutomatic reduction of the dose released
Volume checkDelivered volume inquiry
Flow modesKVO flow rate and fast rate control
PurgePurge button with safety protection
Button lockFlow rate setting lock
Alarms and indicatorsOptical and sound alarms, AC and internal power indication
InterfaceStandard RS232
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Lab Exercises for Biomedical and Nursing Students

A common bench check in a biomedical-engineering lab is a delivery test. Students fill one of the Disposable Syringes with water, set a rate and run the outflow into a Measuring Cylinder, timing the run with a Digital Stop Watch. They compare the collected volume with the delivered volume the pump reports, then repeat the test on the second channel.

For an alarm test, they clamp the outlet line and note how soon each of the three occlusion levels sounds. Nursing students practise loading the syringe, purging the line and locking the rate buttons. The line runs to a Multi-Functional Adult IV Training Arm Model and the pump is clamped to a Saline Stand.

How the Two Channels Work

Each channel has its own drive, so two syringes can run side by side at different rates. When pressure builds behind a blocked line, the pump stops and then backs off the stored push, so less fluid surges out once the line is cleared. The RS232 port carries data to a computer.

Frequently Asked Questions

Why does the occlusion alarm have three levels?
The alarm sounds when pressure in the line rises because it is clamped, kinked or blocked. A low limit alarms sooner, while a higher limit gives fewer nuisance alarms with stiff or long tubing. Which level is used on a patient follows the hospital protocol.

What does the KVO rate do?
KVO means keep vein open. It is a very slow flow the pump keeps up after the set volume is finished, so the line does not stop completely while staff change the syringe.

When is the purge button used?
Purge pushes fluid quickly through a new line to fill it and clear the air before the line is connected. On this pump the purge works through a safety protection step, so a single stray press does not start it.

Can the set rate be protected from accidental changes?
Yes. The flow rate setting buttons can be locked once the rate is entered. A stray touch then cannot alter it mid-run.

How do I check how much has been given?
Use the delivered volume inquiry. The display shows the volume each channel has pushed out since the start.