Syringe Pump Dual Channel Manufacturer,Supplier and Exporter in India
Product Code : EL-SP-3975
Jlab Export is a leading Syringe Pump Dual Channel Manufacturer,and suppliers in India
A syringe pump pushes the plunger of a loaded syringe forward at a set rate to give a small, steady flow. This dual-channel model holds two syringes and runs each one at its own flow rate. A channel that is not needed can be put to sleep, and the occlusion alarm has three limit levels.
Specifications
| Channels | Two, each run at its own flow rate |
| Channel standby | Channel sleeping function |
| Occlusion alarm | 3-level limit setting |
| After an occlusion | Automatic reduction of the dose released |
| Volume check | Delivered volume inquiry |
| Flow modes | KVO flow rate and fast rate control |
| Purge | Purge button with safety protection |
| Button lock | Flow rate setting lock |
| Alarms and indicators | Optical and sound alarms, AC and internal power indication |
| Interface | Standard RS232 |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Lab Exercises for Biomedical and Nursing Students
A common bench check in a biomedical-engineering lab is a delivery test. Students fill one of the Disposable Syringes with water, set a rate and run the outflow into a Measuring Cylinder, timing the run with a Digital Stop Watch. They compare the collected volume with the delivered volume the pump reports, then repeat the test on the second channel.
For an alarm test, they clamp the outlet line and note how soon each of the three occlusion levels sounds. Nursing students practise loading the syringe, purging the line and locking the rate buttons. The line runs to a Multi-Functional Adult IV Training Arm Model and the pump is clamped to a Saline Stand.
How the Two Channels Work
Each channel has its own drive, so two syringes can run side by side at different rates. When pressure builds behind a blocked line, the pump stops and then backs off the stored push, so less fluid surges out once the line is cleared. The RS232 port carries data to a computer.
Frequently Asked Questions
Why does the occlusion alarm have three levels?
The alarm sounds when pressure in the line rises because it is clamped, kinked or blocked. A low limit alarms sooner, while a higher limit gives fewer nuisance alarms with stiff or long tubing. Which level is used on a patient follows the hospital protocol.
What does the KVO rate do?
KVO means keep vein open. It is a very slow flow the pump keeps up after the set volume is finished, so the line does not stop completely while staff change the syringe.
When is the purge button used?
Purge pushes fluid quickly through a new line to fill it and clear the air before the line is connected. On this pump the purge works through a safety protection step, so a single stray press does not start it.
Can the set rate be protected from accidental changes?
Yes. The flow rate setting buttons can be locked once the rate is entered. A stray touch then cannot alter it mid-run.
How do I check how much has been given?
Use the delivered volume inquiry. The display shows the volume each channel has pushed out since the start.
Other Infusion Training Items
- Medical Syringe Pump (single pump, stackable)
- Multifunctional Child IV Training Arm Model
- Plastic Tubing to Fit All Syringes
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 13 November 2026