BOD Incubator with Shaker Manufacturer,Supplier and Exporter in India
Product Code : EL-I-4882
Jlab Export is a leading BOD Incubator with Shaker Manufacturer,and suppliers in India
Flask cultures can be shaken and held at a set temperature from 5 °C to 60 °C in this BOD incubator with a built-in orbital shaker. A geared motor drives the stainless steel tray at 30 to 250 rpm, and a PID controller holds the chamber to ±0.5 °C.
Specifications
| Temperature range | 5 °C to 60 °C |
| Temperature control | Dual-display microprocessor PID controller, ±0.5 °C |
| Shaking speed | 30–250 rpm, variable, with digital rpm meter |
| Timer | 0–24 hours, programmable, with a continuous run mode |
| Flask capacity | 25 flasks of 250 ml or 36 flasks of 100 ml |
| Optional trays | Dedicated tray for 16 flasks of 500 ml; separate clamp plate for 50 ml flasks |
| Shaker tray | Stainless steel sheet with lotus-type flask clamps |
| Cabinet | Triple walled, glass wool between the walls, air circulation fan |
| Chambers | Outer mild steel, painted or powder coated; inner SS 304 stainless steel sheet |
| Viewing and light | Plexiglass window, fluorescent tube light (door or panel switch) |
| Power supply | 230 V AC, 50 Hz (110 V on request), automatic 3 kVA voltage stabiliser |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Microbiology and Biotech Practicals
Students grow a bacterial or yeast culture in broth in Wide Neck Conical Flasks, Erlenmeyer, Borosilicate Glass on the shaker tray. They take a sample at set times and plot a growth curve. The broth is first sterilised in an Autoclave Vertical, and the flasks are inoculated inside a Vertical Laminar Air Flow Cabinet.
The range starts at 5 °C, so the same cabinet can also hold water samples below room temperature. That covers the incubation step of a BOD test, with the shaker switched off. Tissue culture and enzyme work use the shaking and the steady temperature together.
Frequently Asked Questions
Which flask tray should we order?
Order by the flask you use most. The standard tray takes 25 flasks of 250 ml or 36 flasks of 100 ml in lotus-type clamps. A dedicated tray holds 16 flasks of 500 ml, and a separate plate takes 50 ml flasks. Give the flask sizes and counts in your enquiry.
What does the site need before the incubator arrives?
A level floor or bench that can take the weight, space behind for air, and no direct sun or heater nearby. It runs on 230 V AC, 50 Hz (110 V on request), from a properly earthed socket rather than an extension cord.
How can the chamber temperature be checked independently?
Stand a calibrated thermometer in a flask of water on the tray and compare it with the controller display once the chamber has settled. A thermometer taped to the window reads the glass, not the culture.
Why look through the window instead of opening the door?
Each time the door opens, air escapes and the chamber takes a while to recover, so the cultures see a swing in temperature. The plexiglass window and the inside light let you check the flasks with the door shut.
Why let the chamber settle before loading flasks?
Flasks loaded while the chamber is still heating or cooling start at the wrong temperature, and the first points of a growth curve are off. Set the temperature early, wait until the display holds steady, and use the timer to end the run.
Other Incubators and Shakers
For a quote, use Add To Cart or send us a message through the contact page.