PC Based Logic Analyzer Manufacturer,Supplier and Exporter in India
Product Code : EL-LA-10450
Jlab Export is a leading PC Based Logic Analyzer Manufacturer,and suppliers in India
PC Based Logic Analyzer (code EL-LA-10450) is a logic analyser run from a PC that records up to 160 digital channels at a maximum sampling rate of 500 MHz and keeps up to 512 K samples per channel. Its trigger point can sit anywhere in that buffer, so the events before a fault are kept as well as those after it. JLab builds this 160-channel analyser in Ambala, India.
Specifications
| Parameter | Detail |
|---|---|
| Data input channels | Up to 160 |
| Maximum sampling rate | 500 MHz |
| Data buffer | Up to 512 K samples per channel |
| Trigger | 16 levels; continuously variable pre/post-trigger position |
| Data bandwidth | 100 MHz |
| External clock inputs | 8 high-speed inputs, user-definable combinations for clock qualifying |
| Probe impedance | 200 kΩ / 5 pF |
| Threshold voltage | Variable, -6.4 to +6.4 V; up to 8 thresholds at once |
| Trigger output | External, for triggering other instruments |
| Pattern generator | Optional, up to 100 Mbit/s on 8 to 160 channels |
| Quality check | Each logic analyser is visually inspected before dispatch |
| Pack quantity | Each (sold individually) |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Product code | EL-LA-10450 |
| Manufacturer | Jain Laboratory Instruments Pvt Ltd (JLab) — OEM |
| Country of origin | India (made in Ambala, Haryana) |
Timing and State Capture Through One Probe
Timing and state data are captured at the same time through one probe. Timing analysis samples every channel on the analyser’s own clock and shows when edges occur; state analysis samples on the circuit’s clock and shows the value on a bus at each clock edge. The 8 high-speed external clock inputs can be combined in user-defined ways to qualify that clock, so only the cycles of interest are stored.
Setting the Trigger to Catch a Fault
The trigger has 16 levels for fixing the exact point where capture starts, and its pre/post position is continuously variable. When a fault is hard to trigger on directly, the deep 512 K buffer still holds many events around the trigger point. An external trigger output can start another instrument, such as an oscilloscope, at the same moment.
Mixed Logic Levels and Probe Loading
The threshold voltage is variable from -6.4 to +6.4 V, and up to 8 different thresholds can be used at once, so TTL, ECL, 3 V logic, CMOS and RS-232 signals can be watched together. The 200 kΩ / 5 pF probes load the circuit under test only lightly. An optional pattern generator outputs patterns at up to 100 Mbit/s on 8 to 160 channels to drive a circuit under analysis.
Related Logic Analysers and Mixed-Signal Oscilloscopes
- Logic Analyzer — a logic analyser that takes its power from a USB port.
- Mixed/Digital Storage Oscilloscope — four analogue channels, with 16 digital channels as an option.
- Digital Oscilloscope — 4 analogue and 16 digital channels, with optional serial bus decoding.
More instruments of this kind are in Logic Analyzers, part of Test and Measurement Equipment.
Request a Quote
To order, use Add To Cart or write through the contact page, giving the quantity, whether the optional pattern generator is needed and the delivery address.