Twenty-eight pipettes stand upright on this stand, held by a top disc and located at the tips by a lower disc with pilot holes. Both discs move along a square polypropylene-coated rod, 375 mm long, so they can be set for short or long pipettes. The rod screws into a heavy base 225 mm across.
Stand Construction
| Capacity | 28 pipettes |
| Maximum pipette diameter | 14 mm |
| Base | Heavy, 225 mm in diameter |
| Rod | Square, polypropylene coated, 375 mm long, screwed into the base |
| Top disc | Holes that hold the pipettes |
| Lower disc | Pilot holes where the tips rest, liquid drains to the base |
| Adjustment | Discs set on the rod to suit the pipette length |
| Alignment | Arrows on the discs kept parallel to centre the holes |
| Build | Stable, non-corrosive, detachable |
| Minimum order quantity | 10 units |
| Dispatch time | Usually 4–6 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Redox Titration and Water Testing Practicals
In the class 12 titration of potassium permanganate against oxalic acid or Mohr’s salt, the reducing solution is measured with a one-mark pipette. Students take one from the Bulb Pipettes, Class B Soda Glass, One Mark JLab range. They fill it with a Pipette Filler Pump and run it into a Conical Flask. Before class, the technician sets the discs to the pipette length and fills the stand, so each student collects a clean pipette.
In a water testing practical, students find the chloride in tap water and well water by titration with silver nitrate. A separate pipette for every sample stands in its own hole, marked with the sample name, so a salty sample never carries over into the next.
Frequently Asked Questions
Why must the arrows on the two discs line up?
The top disc holds each pipette and the lower disc has the pilot hole where its tip rests. Keeping the arrows parallel puts every pilot hole straight under its top hole, so the pipette hangs straight and its tip drains into the hole below.
How are the discs set for short and long pipettes?
Both discs slide on the square rod and can be fixed at any height. Set the top disc so the upper end of the pipette stands clear, then bring the lower disc to where the tip rests. A short graduated pipette and a long bulb pipette need different settings.
Why keep pipettes upright rather than lying flat?
In a pipette laid flat, liquid left inside can creep back towards the upper end. There it wets the filler at the next use and carries traces into it. Standing tip down, the liquid runs out of the tip instead.
Can a pipette go back on the stand with liquid still in it?
Empty it and rinse it first. A pipette returned with sample inside drips into the pilot hole and onto the base. The next user then picks up a pipette that still holds the old solution.
Should students shake out the drop left in the tip?
Not during a measurement. A delivery pipette is made to leave that small drop in the tip, so it is not blown or shaken out. After the practical, rinse the pipette with water and stand it tip down so the rest drains away.