• +91-85699-09696

Plasma Extractor (Grade 302 Steel) Manufacturer,Supplier and Exporter in India

Plasma Extractor (Grade 302 Steel)

Product Code : EL-BBE-3556
Jlab Export is a leading Plasma Extractor (Grade 302 Steel) Manufacturer,and suppliers in India

Separating plasma by hand needs a steady push on the bag, and this plasma extractor gives it with a spring-loaded front panel. The centrifuged bag sits behind the panel, which presses it so the liquid flows into a transfer bag. The body is grade 302 stainless steel, and the unit is small enough to carry between benches.

Specifications

UseExtracting blood components from centrifuged bags
PressureSpring-loaded front panel
ConstructionStainless steel, grade 302
BuildPortable
Minimum order quantity10 units
Dispatch timeUsually 4–6 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Practicals for MLT and Blood Bank Trainees

For practice, students use a bag set filled with water instead of blood. They release the front panel, slide the full bag behind it with the outlet at the top and let the spring take over. One student watches the transfer bag while another clamps the tube on a signal, which trains the timing the real job needs.

Afterwards they weigh the transfer bag on the Blood Bank Scale (Auto Calibration) and compare the volume with their target. Timing several runs with a Digital Stop Watch shows how the flow slows as the bag empties. Teachers can close with a short session on wiping down the steel body and checking the spring before the next use.

Frequently Asked Questions

Can it be used for components other than plasma?
Yes. It presses any centrifuged bag, so the top layer moves to a transfer bag whatever the separation step, for example platelet-rich plasma. Which component is taken is set by the blood bank procedure.

What stays behind in the main bag?
The plasma moves to the transfer bag, while the packed red cells and the thin buffy coat layer above them stay in the main bag. How far to take the extraction follows the blood bank’s own protocol.

What does the operator do during one extraction?
Release the panel, place the bag, open the outlet and let the spring press. Watch the layers, clamp the tube at the right point, then seal and separate the bags. Each step is done by hand, so training matters.

Why is the body made of grade 302 stainless steel?
Stainless steel needs no paint and does not rust in normal use. Spills of blood or plasma can be wiped off and the surface disinfected between runs.

Other Blood Bank Equipment

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 13 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696