Undercounter Blood Bank Refrigerators Manufacturer,Supplier and Exporter in India
Product Code : EL-BBE-3561
Jlab Export is a leading Undercounter Blood Bank Refrigerators Manufacturer,and suppliers in India
Built to fit under a worktop, this blood bank refrigerator stores up to 50 bags of 450 ml in two stainless steel floating drawers. It is factory set to +3.5°C (+38°F) and holds the product within one degree either side. A surveillance module adds an alarm, a digital temperature display and a chart recorder.
Specifications
| Factory set point | +3.5°C (+38°F) |
| Product temperature held | Within +1 / -1°C |
| Compressor | Heavy-duty, 1/4 hp |
| Defrost | Off-cycle, automatic |
| Temperature surveillance module | Alarm, digital temperature display and chart recorder |
| Drawers | Two stainless steel floating drawers |
| Storage | Up to 50 bags of 450 ml |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Practicals for Blood Bank Technicians
Technician students keep a temperature log. They read the digital display at set times and compare it with a Minimum Maximum Thermometer placed in a drawer. Then they lay the chart trace beside their written readings and mark each door opening.
In an alarm drill, the instructor shows how the module responds when the temperature drifts out of range, and students write down the steps they would take. Water-filled practice bags closed on a Blood Bag Sealer (with LED Indicators) are used to practise loading the drawers by blood group, oldest bags at the front.
Frequently Asked Questions
What should staff do when the alarm sounds?
First check that the door is fully shut and read the display. Many alarms come from a door left ajar or a long loading session. If the reading stays out of range, follow the blood bank’s own procedure for moving the bags to another refrigerator.
What goes in the refrigerator register?
Most blood banks keep a register beside the refrigerator for every bag that goes in or out, with the date, time and initials. How the register is laid out, and who signs it, is set by your blood bank’s procedure.
What happens during defrost?
Defrost here is off-cycle and automatic: frost on the cooling coil melts while the compressor rests between cycles, without a separate heater. Staff do not need to empty the drawers for defrosting.
How many bags do the drawers hold?
The two floating drawers hold up to 50 bags of 450 ml between them. Pulling a drawer out lets staff read the bag labels and take the oldest bag first.
What should happen in a power cut?
Keep the door shut so the cold air stays in, and watch the display. If the power will be off for long, the bags are moved to a working unit as the blood bank’s procedure states.
Other Blood Bank Storage Units
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 13 November 2026
