Blood Collection Monitor Manufacturer,Supplier and Exporter in India

Blood Collection Monitor

Product Code : EL-BBE-3549
Jlab Export is a leading Blood Collection Monitor Manufacturer,and suppliers in India

During a donation this blood collection monitor weighs the filling bag and stops the collection at the volume set by the operator. Volume is set in 1 ml steps, and a motorised pinch closes the tube at the end. The unit tares the empty bag itself, totals grams and time as it runs, and alarms if the flow falls below 15 ml/min.

Specifications

ControlMicrocontroller based program
Volume settingIn 1 ml increments
TareAutomatic
During collectionPause, and change of the preset volume
ReadoutsSet volume, grams and time totalised
End of collectionMotorised pinching of the tube, audio alarm
Low flow alarmAudio-visual, when flow is below 15 ml/min
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Donation Practicals Without a Donor

Blood bank and nursing trainees can learn the monitor on a dry run. They set up a practice bag on the monitor beside the Donor Couch and run water into it by gravity from a raised bag. They enter a target volume and watch the auto tare, the running total and the pinch at the end.

To meet the low-flow alarm, one trainee partly closes the line with a roller clamp until the flow drops and the alarm sounds. They also pause a run, change the preset volume and restart it. A weighing check with masses from the Analytical Weight Box - 1g to 500g completes the pre-use routine.

Frequently Asked Questions

Can the set volume be changed during a collection?
Yes. The operator can pause the collection and change the preset volume, then let it carry on. The monitor then pinches the tube at the new figure instead of the old one.

Why does the low-flow alarm sound?
It sounds when the flow falls below 15 ml/min. Common causes are a kinked or clamped line, a bag hanging too high or a needle position that needs attention. Trained staff check the donor and the line as the hospital protocol sets out.

What happens when the set volume is reached?
The motorised pinch closes the tube so no more blood runs into the bag, and an audio alarm calls the operator. Staff then finish the donation and seal the tube as the hospital protocol describes.

What does the time total tell the operator?
It shows how long the collection has been running. Read with the grams total, it gives a picture of how the flow is going, so a slow donation is noticed early.