RIA Vials Manufacturer,Supplier and Exporter in India
Product Code : EL-V-115
Jlab Export is a leading RIA Vials Manufacturer,and suppliers in India
RIA vials are small round tubes, 12 x 75 mm, used in radioimmunoassay, coagulation and bacteriology work. The plastic sets their limits. Polypropylene is clear, takes 3000 RCF in a centrifuge and resists common acids, alkalis and solvents at room temperature. Polystyrene is transparent, takes 1400 RCF and suits mild bases and weak acids, but not organic solvents. A 12 mm cap fits both.
Specifications
| Tube size | 12 x 75 mm |
| Polypropylene tube | Clear, up to 3000 RCF, takes common acids, alkalis and solvents at room temperature |
| Polystyrene tube | Transparent, up to 1400 RCF, takes mild bases and weak acids, not organic solvents |
| Cap | For 12 mm RIA tubes |
| Typical uses | RIA, coagulation and bacteriology |
| Minimum order quantity | 100 units |
| Dispatch time | Usually 3–5 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Centrifuge and Solvent Practicals
Leaf pigment extraction shows why the plastic matters. Students grind spinach leaves with acetone in a Porcelain Pestle and Mortar and move the green extract into a polypropylene tube with a Pasteur Pipette. A short spin in the Centrifuge with Timer and Speed Control settles the leaf debris, and the clear extract is spotted for paper chromatography. The polystyrene tube stays out of this exercise, because acetone attacks it.
Before any run, teachers have students fill pairs of tubes to the same level, place each pair opposite in the rotor and close the lid. Nobody opens the lid until the rotor has stopped.
Frequently Asked Questions
How do I keep the tubes within their RCF limit?
RCF depends on both the speed and the rotor radius, so the same rpm gives more force in a larger rotor. Use the chart or setting of your centrifuge to find the rpm that stays under 3000 RCF for polypropylene and 1400 RCF for polystyrene.
Which tube should hold an organic solvent?
Use polypropylene, which takes common acids, alkalis and solvents at room temperature. Organic solvents such as acetone attack polystyrene, which may turn cloudy, crack or soften. Keep the polystyrene tube for water-based samples, mild bases and weak acids.
How should the tubes be balanced in the rotor?
Fill tubes in pairs to the same level and place each pair directly opposite. Balance polypropylene against polypropylene and polystyrene against polystyrene, since the two plastics differ in weight. With an odd number of samples, add a tube of water as the counterweight.
Should the caps be on during spinning?
Yes. Push a 12 mm cap onto every tube before the run. The cap holds back spray if a tube leaks and stops the sample drying out. Open the centrifuge only when the rotor has come to a complete stop.
Other Tubes for Small Samples
- Test Tube with Screw Cap (Polypropylene)
- Centrifuge Tube Conical Bottom
- Scintillation Vial
- Vials (graduated storage vials)
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 14 November 2026