Small Animal Incinerator Manufacturer,Supplier and Exporter in India
Product Code : JL-I-2431
Jlab Export is a leading Small Animal Incinerator Manufacturer,suppliers and Exporter in India, Small Animal Incinerator Uruguay (Montevideo), Small Animal Incinerator Uzbekistan (Tashkent), Small Animal Incinerator Venezuela (Caracas), Small Animal Incinerator Vietnam (Hanoi), Small Animal Incinerator Yemen (Sana'a), Small Animal Incinerator Zambia (Lusaka), Zimbabwe (Harare), Eswatini (Mbabane) (Lobamba), Ethiopia (Addis Ababa), Fiji (Suva), Gabon (Libreville), Gambia (Banjul), Georgia (Tbilisi), Ghana (Accra), India (Delhi, Mumbai, Kolkatta, Chennai), Indonesia (Jakarta), Iraq (Baghdad), Ivory Coast (Yamoussoukro), Jamaica (Kingston), Jordan (Amman), Kazakhstan (Astana), Kenya (Nairobi), Kiribati (Tarawa), Kosovo (Pristina), Kuwait (Kuwait City), Kyrgyzstan (Bishkek), Laos (Vientiane), Latvia (Riga), Lebanon (Beirut), Lesotho (Maseru), Liberia (Monrovia), Libya (Tripoli), Lithuania (Vilnuis), Luxembourg (Luxembourg), Malawi (Lilongwe), Malaysia (Federal Territory of Kuala Lumpur), Maldives (Malle), Mali (Federal Territory of Kuala Lumpur), Malta (Male), Mauritania (Nouakchott), Mauritius (Port Louis), Mexico (Mexico City), Mongolia (Ulaanbaatar), Bulgaria (Sofia), Burkina Faso (Ouagadougou), Burundi (Gitega), Cambodia (Phnom Penh), Cameroon (Yaoundé), Cape Verde (Praia), Central African Republic (Bangui), Chad (N'Djamena), Chile (Santiago), Colombia (Bogota), Comoros (Moroni), Congo (Kinshasa), Costa Rica (San José), Croatia (Zagreb), Cuba (Havana), Cyprus (Nicosia), Czech Republic (Prague), Denmark (Copenhagen) ,Djibouti (Djibouti City), Dominican Republic (Santo Domingo), DR Congo (Kinshasa), Ecuador (Quito), Egypt (Cairo), El Salvador (San Salvador), Equatorial Guinea (Malabo), Eritrea (Asmara), Estonia (Tallinn)
Specification |
U.S
Standard |
Metric
System |
|
Length |
55"
(69" With Cremation Burner) |
1.3m
(1.7m with cremation burner) |
|
Width |
40"
(54" With Control Panel) |
1.0m
(1.3m with control panel) |
|
Height |
65"
(75" With Afterburner) |
1.6m
(1.9m with afterburner) |
|
Weight |
5,200
lbs. |
2,358
Kg |
|
Gas
Pressure |
Natural
Gas 7" W.C./Propane Gas 11" W.C. |
Natural
Gas 1.7 kPa W.C. |
|
Propane
2.7 kPa W.C. |
|
||
Power
Requirements |
110V,
Single Phase, 30 AMPS |
|
|
Incineration
Rate |
50
lbs/hour |
22
Kg/hour |
|
Weight
Capability |
200 lbs |
90 Kg |
|
Stack
Height From Grade: |
Minimum
15' |
4.5m |
|
Stack
Sections |
18"
O.D 4 1/2" Firebrick Walls/Cast-able Refractory Lining/(Hearth and
Ceiling) |
0.4m
O.D |
|
Refractory/Insulation |
3"
1900 - Board Insulation |
0.11m
Firebrick Walls/Cast-able Refractory Lining(Hearth and Ceiling) |
|
0.07m
1900 - Board Insulation |
|
||
Chamber
Dimensions |
Length:
32" |
0.8m |
|
Width:
26" |
0.6m |
|
|
Height:
25" |
0.6m |
|
|
12
Cubic Feet |
0.288
Cubic Meters |
|
|
Burner
output |
Maximum
Input Rating 750,000 BTU's per hour/Afterburner Maximum 400,000 BTU's per
hour/Modulation Minimum 100,000 BTU's per hour/Cremation Burner 350,000 BTU's
per hour |
791,250
KJ per hour/422,000 KJ per hour/105,500 KJ per hour 369,250 KJ per hour |
|
Air
Requirements |
Outside
air inlet louvers in the room/located at or below burner height, capable of
passing 2,500 CFM of free air |
Outside
air inlet louvers in the room located at or below burner height, capable of
passing 1.173 Cubic meters per second |
|