• +91-85699-09696

Traction Table Manufacturer,Supplier and Exporter in India

Traction Table

Product Code : EL-PE-3843
Jlab Export is a leading Traction Table Manufacturer,and suppliers in India

This traction table has its traction controls built in, so the couch and the pulling unit work as one station. It runs in static or intermittent mode. Hold and rest times appear on digital displays, and treatment time is set with feather-touch keys. A patient safety switch triggers an audio-visual alarm, and at the end of the treatment the alarm sounds and the pull is released.

Specifications

ModesStatic or intermittent
Hold and rest timeShown on digital displays
Treatment timeFeather-touch keys with digital display
Patient safety switchWith audio-visual alarm
End of treatmentAlarm sounds and traction force is released
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Practicals at the Traction Station

Students begin by locating each control and display and learning what it does. They then test the patient safety switch with no one on the table. Pressing it during a run should set off both the sound and the light of the alarm.

Next, they set a short treatment time on the keys and time it with a Digital Stopwatch, checking that the force is released when the alarm sounds. With a Measuring Tape they measure the rope line from the unit to the harness hook and check that it runs straight.

Frequently Asked Questions

What does the patient safety switch do?
The patient holds the switch during treatment. Pressing it sets off the audio-visual alarm, so staff know at once that the patient needs them. Test it before every session with the table empty, and do not start if the alarm fails.

Can the hold and rest times be read during a session?
Yes. In intermittent mode the hold and rest times show on their own digital displays, and the treatment time has a separate display. Staff can see the settings from the side of the table without opening a menu.

How are the table and harnesses cleaned between patients?
Switch off and unplug first. Wipe the upholstery and the control panel with a damp cloth and a mild cleaner, never spray liquid onto the keys, and let the surfaces dry. Wash or wipe harnesses as their material allows and keep a spare set ready.

How often should the traction rope be checked?
Look along the full length of the rope before each day of use for fraying, flattening or knots, and check the hook and pulley. Replace a worn rope at once. A technician should check the force output and the release at regular service visits.

More Traction Units and Tables

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 13 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us