Product Code : EL-SLE-5636
Jlab Export is a leading Autoclave Manufacturer,and suppliers in India
Autoclave (code EL-SLE-5636) is a double-wall laboratory autoclave with a stainless steel chamber and a one-piece heavy-duty gun metal lid, running on 220 V, 50 Hz, used to sterilise culture media, glassware and instruments with steam under pressure in school, college and microbiology teaching labs. The lid carries a pressure gauge, whistle and safety valves. It is made by Jain Laboratory Instruments Pvt Ltd (JLab) at its works in Ambala, India.
Get a quote: use the Add To Cart enquiry button below, or send your quantity and destination through the contact page.
Specifications
| Parameter | Detail |
|---|---|
| Construction | Double wall |
| Chamber | Stainless steel |
| Lid | Heavy-duty gun metal, single piece |
| Power supply | 220 V, 50 Hz |
| Fittings on the lid | Pressure gauge, whistle and safety valves (listed as double safety valves) |
| Seal | Gasket between the lid and the body |
| Water level | Water level indicator showing the water inside the unit |
| Steam release | Steam release valve |
| Chamber size, heater rating and working pressure | Not stated in this listing — JLab confirms them in the quotation |
| Quality check | Each autoclave is visually inspected before dispatch |
| Pack quantity | Each (sold individually) |
| Minimum order quantity | 10 units |
| Dispatch time | Usually 7–10 working days |
| Product code | EL-SLE-5636 |
| Manufacturer | Jain Laboratory Instruments Pvt Ltd (JLab) — OEM |
| Country of origin | India (made in Ambala, Haryana) |
How Does It Compare with Other JLab Autoclaves?
| Model | Body and lid (as listed) | Other listed details |
|---|---|---|
| This autoclave (EL-SLE-5636) | Double wall; stainless steel chamber; one-piece gun metal lid | 220 V, 50 Hz; pressure gauge, whistle, safety valves, water level indicator, steam release valve |
| Autoclave Electrical | Aluminium, 12 x 12 in | Pressure gauge, safety valve, steam and vacuum release valves; inner container, tripod and mild steel stand |
| Vertical Autoclaves | Double walled; stainless steel boiler; stainless steel or gun-metal lid | Electrically heated; adjustable pressure, 10 to 20 psi |
| Laboratory Autoclave | All stainless steel or aluminium, seamless, vertical | Pressure range 15 to 18 psi; chamber sizes listed |
Choose this model when you want a double-wall unit with a gun metal lid and a water level indicator on the standard 220 V supply; the aluminium electrical autoclave comes with an inner container and stand, and the vertical and laboratory autoclaves state adjustable or set pressure ranges and chamber sizes.
What Is the Autoclave Used For?
Water heated in a sealed chamber builds up steam pressure, and pressurised steam reaches temperatures above the normal boiling point of water. That is how an autoclave sterilises culture media, petri dishes, pipettes and dissecting instruments before microbiology practicals, and how used cultures are made safe before disposal. In schools and colleges it is part of the microbiology and biotechnology lab, where students prepare nutrient agar, autoclave it in flasks and pour plates. Each run should be checked with the sterilisation indicators your laboratory procedure specifies.
Before switching on, fill water up to the level shown on the indicator and check that the gasket is seated and the valves are free. Load items loosely so steam can reach every surface, loosen caps on bottles, and close the lid evenly. After the cycle, switch off and wait until the pressure gauge shows no pressure, then open the steam release valve before lifting the lid. An autoclave is a pressure vessel, so it should be operated only by trained staff.
What to Specify When Ordering
- Chamber size — the listing does not state it; tell JLab the volume you need for your batch of media and glassware.
- Electrical supply — this model is listed for 220 V, 50 Hz; state your supply if it differs.
- Quantity — the minimum order is 10 units.
- Consumables — petri dishes and other lab glassware can be quoted on the same enquiry.
Frequently Asked Questions
What is the autoclave made of?
The chamber is stainless steel inside a double-wall body, and the lid is a single piece of heavy-duty gun metal with a gasket between lid and body.
What power supply does it need?
It is listed for 220 V, 50 Hz. If your mains supply is different, mention it in your enquiry.
Which safety and control fittings does it have?
The lid has a pressure gauge, a whistle and safety valves, listed as double safety valves, and the unit has a water level indicator and a steam release valve.
What chamber size and working pressure does it have?
The listing does not give the chamber size, heater rating or working pressure. Ask JLab to confirm these in the quotation, or compare the vertical and laboratory autoclaves, which state their pressure ranges.
How do I open it safely after a cycle?
Switch off, wait until the gauge shows no pressure, open the steam release valve, and only then lift the lid away from your face.
What is the minimum order and dispatch time?
The minimum order is 10 units. Orders usually leave within 7–10 working days after a visual inspection of every unit; export transit time depends on the destination.
What should an export quotation request include?
Send the quantity, the destination country and port or city, delivery terms (for example FOB or CIF), your mains voltage, any packing or labelling needs and a tender reference if there is one.
Who manufactures this autoclave?
Jain Laboratory Instruments Pvt Ltd, trading as JLab, at its works in Ambala, Haryana, India.
OEM Manufacturer
JLab is the trading name of Jain Laboratory Instruments Pvt Ltd, a manufacturer of laboratory equipment and microbiology lab apparatus in India, incorporated in 2017 and based on Hargolal Road, Ambala, Haryana. This autoclave is built at JLab’s own works rather than sourced from a trader, so schools, colleges, dealers and importers deal directly with the maker, each unit is visually inspected before dispatch, and spares and repeat orders are handled in-house. Its registrations include GSTIN 06AADCJ9848D1ZE and Legal Entity Identifier 549300DTGS77DGYD6N03. JLab exports worldwide and ships to buyers in every region — for example Poland in Eastern Europe, Argentina in South America, Taiwan in East Asia, Yemen in the Middle East and Eswatini in Southern Africa. For tender supply, see the JLab lab tenders page.
Related Microbiology Lab Equipment
- Petri Dish — borosilicate glass petri dishes for growing cultures on agar.
- Autoclave Electrical — an aluminium electrical autoclave with inner container and stand.
- Vertical Autoclaves — electrically heated, double-walled autoclaves with adjustable pressure.
- Water Bath Single Wall — a stainless steel electric water bath for warming tubes and flasks.
See all items in the School Lab Equipment range.
Request a Quote
Quotes come direct from the manufacturer. Use the Add To Cart enquiry button on this page, or send the quantity (minimum 10 units), the chamber size you need, your mains supply and the delivery location through the contact page.
Last updated: 4 October 2026