• +91-85699-09696

Autoclave Horizontal (Without Steam Jacket) Manufacturer,Supplier and Exporter in India

Autoclave Horizontal (Without Steam Jacket)

Product Code : EL-A-2277
Jlab Export is a leading Autoclave Horizontal (Without Steam Jacket) Manufacturer,and suppliers in India

Built like the vertical models but laid on its side, this autoclave takes its load from the front and has no steam jacket around the chamber. Trays slide straight in at working height instead of being lowered from above. It comes in six chamber sizes from 250 x 450 mm to 550 x 750 mm, with heaters of 1.5 to 5.0 kW.

Specifications

LayoutHorizontal chamber, loaded from the front
ConstructionAs the vertical autoclave, but without steam jacket
Chamber sizes (mm) and heater load250 × 450 (1.5 kW), 300 × 500 (2.0 kW), 350 × 550 (3.0 kW), 400 × 600 (4.0 kW), 450 × 600 (4.0 kW), 550 × 750 (5.0 kW)
OptionalPressure gauge, compound gauge, automatic low water level cut-off, pressure control switch
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Sterilising Practice for Students

In nursing and paramedical labs, students sort Stainless Steel Forceps and other instruments into a Kidney Tray, wrap the set and label it with the date. The wrapped sets travel on an Instrument Trolley to the open chamber, where they slide in flat without being lifted over a rim.

Microbiology classes use the same chamber to make waste safe. Used culture plates go into an autoclavable bag, which is left loosely closed so steam can get in and set in a tray before the run. Teachers can time a full cycle with the class, from switching on to the gauge showing zero, and discuss why the door stays shut until then.

Frequently Asked Questions

What does having no steam jacket mean?
A jacket is an outer steam space that keeps the chamber walls hot between and during runs. Without one, the wall warms up with the load each time. The construction is simpler, and the chamber starts each run from room temperature.

What does the optional compound gauge show?
It reads pressure above atmospheric and vacuum below it on one dial. After a run you can see the chamber come back to zero, and spot a slight vacuum as steam condenses, which makes the door hard to open.

Is a pressure gauge included as standard?
The pressure gauge is one of the options, along with the compound gauge. Order one of them, since the operator needs to read the chamber pressure to start timing and to know when the run has finished.

How should bottles of liquid be loaded in a horizontal chamber?
Stand them in a tray with a little water in it, fill each bottle only part way and leave space between them. The tray catches any spill and keeps glass from rolling. Liquids need a slow cool-down before the door is opened.

How should the autoclave be left between term breaks?
Drain all the water, wipe the chamber dry and leave the door slightly open so the gasket does not stay pressed flat. Switch off and unplug it. Before the next use, refill with fresh water and run an empty cycle.

Other Autoclaves to Compare

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 12 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us