Autoclave Horizontal Manufacturer,Supplier and Exporter in India
Product Code : EL-A-1949
Jlab Export is a leading Autoclave Horizontal Manufacturer,and suppliers in India
Lying on its side with a door at the front, this horizontal autoclave lets trays of media, glassware and wrapped packs slide straight in. Saturated steam under pressure does the sterilising. It carries a drain cock, an inlet and a double safety valve, and is supplied complete but without dressing bins.
Specifications
| Type | Horizontal, loaded from the front |
| Fittings | Drain cock, inlet and double safety valve |
| Supplied | Complete, without dressing bins |
| Optional fittings | Automatic low-water level cut-off device, pressure control switch, water level arrangement |
| Optional dressing bins | Various sizes |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Lab Work with a Front-Loading Autoclave
Biotechnology and microbiology students wrap glass Petri Dish sets in paper, lay them on a tray and slide them in for sterilising. Agar sterilised in the same run is poured into the dishes inside a Horizontal Laminar Flow Cabinet, left to set and then streaked with a culture.
In nursing and paramedical labs, students fill a Sterilizer Shallow Dressing Drum with gauze, slide its belt to open the side perforations and lay it in the chamber. After the run the belt is closed again so the contents stay covered until use.
Frequently Asked Questions
Should I choose a horizontal or a vertical autoclave?
A horizontal autoclave loads from the front, so heavy trays and packs go in without being lifted over a top rim. A vertical autoclave loads from the top and takes up less floor area. Both sterilise with the same steam process.
What does the optional pressure control switch do?
It switches the heating on and off to hold the chamber at the pressure you set. The operator then does not have to adjust the heat by hand during the holding time.
Why do wrapped packs come out wet?
Packs come out damp when they are packed too tightly, pressed against the chamber wall, or taken out before the condensed water has dried off them. Leave space between packs and let the load stand in the warm chamber after the pressure falls.
How often should the water be drained?
Drain it through the drain cock at the end of each working day, or sooner if it looks cloudy, and refill with clean water. Old water leaves scale on the chamber walls and can carry residues onto the next load.
Other Front and Top-Loading Autoclaves
- Autoclave Vertical (same fittings, loaded from the top)
- Autoclave Horizontal (Without Steam Jacket) (horizontal, without steam jacket)
- Rect. Horizontal Autoclave (rectangular chamber)
- Horizontal Autoclave (large floor model)
For a quote, use Add To Cart or send us a message through the contact page.