• +91-85699-09696

Centrifuge Angle Rotor Head Doctor Pattern Manufacturer,Supplier and Exporter in India

Centrifuge Angle Rotor Head Doctor Pattern

Product Code : EL-A-1952
Jlab Export is a leading Centrifuge Angle Rotor Head Doctor Pattern Manufacturer,and suppliers in India

An angle rotor head tilts each 15 ml tube at a fixed angle in this doctor-pattern centrifuge, so solids pack quickly against the outer wall and slide to the bottom. It runs at 4000 to 5000 rpm on a speed regulator and comes with a cord and plug. The head is made for 4, 6, 8 or 12 tubes.

Specifications

RotorAngle head
Speed4000 to 5000 rpm
Speed controlSpeed regulator
Tube size15 ml
Capacity4, 6, 8 or 12 tubes
Power connectionCord and plug
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Biochemistry Practicals Using the Centrifuge

To isolate casein, students warm skimmed milk, add dilute acetic acid until the curd forms, and spin the mixture in a Centrifuge Tube Conical Bottom. The whey is poured off, and the pellet is washed and spun again.

The washed casein is dissolved and tested for protein by the biuret method, with the colour read on a Digital Photo Colorimeter. When serum is separated from clotted blood, a Pipette, Pasteur lifts the clear layer off without disturbing the cells. Because the force rises with the square of the speed, going from 4000 to 5000 rpm raises it by more than half.

Frequently Asked Questions

Why use an angle rotor head instead of a swing-out rotor?
In an angle head the tubes stay tilted, so particles travel only a short way before they reach the outer wall and slide down into a pellet. A swing-out rotor swings the tubes out flat and gives a level boundary between layers.

Can I spin an odd number of tubes?
Yes, with a balance tube. Fill a spare 15 ml tube with water to the same level as the sample and place it in the pocket opposite. Every pair across the head must match in weight before you start.

How should the speed regulator be used?
Start with the regulator at its lowest setting and turn it up slowly to the speed the method asks for. At the end, turn it back down and let the head coast to a stop on its own; never slow it by hand.

What does doctor pattern mean?
It names a small bench centrifuge of the size kept in a doctor’s room or a small lab, taking a few 15 ml tubes at a time. This one is made with 4 to 12 tube positions.

Which tubes can go in the angle head?
Use 15 ml tubes that sit snugly in the pockets, in glass or polypropylene made for centrifuging. Conical-bottom tubes give a tight pellet that is easy to see and keep when the liquid is poured off.

Other Bench Centrifuges and Tubes

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 6 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us