Sized for a bench, this 20 L table top autoclave runs under automatic control, with an automatic water inlet. It sterilises at 121 °C or at 134 °C, and its auto-dry mode dries the load before it is taken out. The unit runs on a 220 V AC supply and draws 2000 W.
Specifications
| Chamber capacity | 20 L |
| Control | Automatic control and water inlet |
| Drying | Auto-dry mode |
| Sterilising setting | 121 °C (249.8 °F) at 1.1 kg/cm² (15.64 lb/in²) |
| Second setting | 134 °C (273.2 °F) at 2.1 kg/cm² (29.85 lb/in²) |
| Power | 220 V AC, 50/60 Hz, 2000 W |
| Overall size | 624 x 430 x 621 mm (W x H x D) |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Experiments That Start in the Autoclave
In a biotechnology or pharmacy lab, students sterilise culture media in a polypropylene Conical Flask (Polypropylene) at the 121 °C setting, with the screw cap threads left loose. The media are then poured into sterile glass Petri Dish sets inside a Vertical Laminar Air Flow Cabinet for plating and antibiotic disc tests.
Teachers can run the 134 °C setting with clean, wrapped metal instruments and glassware. They then explain that media stay at the lower setting because the sugars and proteins in them break down at the higher one. Comparing a pack dried by the auto-dry mode with one taken out early shows students why dry packs matter.
Frequently Asked Questions
When should I use 121 °C and when 134 °C?
Use 121 °C for culture media, liquids and plastics marked autoclavable. The 134 °C setting suits metal instruments and glassware that take the higher heat, and it needs a shorter hold. Follow your lab method for the holding time.
What does the auto-dry mode do?
After the sterilising stage, the auto-dry mode dries the load inside the chamber, so wrapped packs and glassware come out dry and ready to store. Liquid loads do not need it.
What power point does it need?
It runs on 220 V AC at 50 or 60 Hz and draws 2000 W. Plug it into its own earthed socket rated for that load, not into a shared extension board.
Will it fit on a standard lab bench?
Its outside size is 624 mm wide, 430 mm high and 621 mm deep. Leave some space at the sides and back for air to move, and room in front to open the door fully.
What water should I use in it?
Use distilled or deionised water. Tap water leaves scale inside the chamber and on the heating parts, and the deposits build up with every cycle.