Autoclave Laboratory Portable Manufacturer,Supplier and Exporter in India
Product Code : EL-A-1950
Jlab Export is a leading Autoclave Laboratory Portable Manufacturer,and suppliers in India
Made of heavy-duty stainless steel, this portable laboratory autoclave is a small steam steriliser for a few flasks of media or a basket of glassware. Its one-piece body, with no joint in the wall, measures 300 x 300 mm (diameter x height). It has a double safety valve, a steam release valve and a 2.5 inch special gauge.
Specifications
| Material | Heavy-duty stainless steel |
| Seamless body size | 300 x 300 mm (diameter x height) |
| Joined body | Made in two other sizes |
| Gauge | 2.5 inch special gauge |
| Valves | Double safety valve and steam release valve |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Practicals in a Small Microbiology Lab
Schools and small college labs use a portable autoclave to sterilise the broth and agar needed for one practical class. After the run, students cool the agar, pour plates and streak a culture with an Inoculating Loop Nichrome Wire flamed before and after each streak.
The plates then spend the night in an Incubator Bacteriological. Tubes of autoclaved and unautoclaved broth go in beside them, and next day the class compares how cloudy the two sets are. Teachers also use the gauge to show that pressure rises as water boils in a closed vessel. Steam under pressure is hotter than water boiling in an open pan.
Frequently Asked Questions
How do I read the gauge during a run?
The gauge shows the steam pressure inside the body. Start timing only when the needle reaches the pressure your lab method asks for, then turn the heat down to hold it there. The needle must be back at zero before the lid is opened.
What is the steam release valve used for?
At the start it stays open while the water heats, so air is pushed out and the body fills with steam alone. At the end it is opened only when the gauge reads zero, to let the last steam out before the lid is lifted.
What is the difference between the one-piece and joined bodies?
The 300 x 300 mm body is made in one piece, with no joint in its wall. The joined versions are built from more than one piece and come in two other sizes, so a lab can pick the body that suits its load.
What mistakes do students make with a portable autoclave?
Too little water, caps screwed down tight and closing the steam release valve before the air is out all give a poor run. Opening the lid before the gauge reads zero makes liquids boil over and can scald hands.
Other Portable and Bench Autoclaves
- Portable Autoclave (stainless, with a replaceable heater)
- Laboratory Autoclave (vertical body with no joints)
- Autoclave Electrical (aluminium body)
- Table Top Autoclave (20 L) (automatic control, auto-dry)
For a quote, use Add To Cart or send us a message through the contact page.