Digital Photo Colorimeter

Product Code : EL-BTI-2156
Jlab Export is a leading Digital Photo Colorimeter Manufacturer,and suppliers in India

This digital colorimeter reads optical density from 0 to 1.99 on an LED display and needs as little as 1 ml of coloured solution. Glass filters on a rotating disc cover 400 to 700 nm, in a set of eight or five. A built-in shutter keeps light off the photocell between readings, and a battery or mains version is also available.

Specifications

Filters, 8-filter model400, 450, 490, 520, 540, 570, 620, 680 nm
Filters, 5-filter model450, 490, 540, 620, 680 nm
Wavelength range400–700 nm, glass filters on a rotating disc
OutputOD 0 to 1.99
ResolutionOD 0.01
Display2½ digit LED
Minimum volume1 ml
Detector and light sourcePhotocell/photodiode; 6.8 V, 300 mA light source
Power, size and weight230 V ±10% AC, 50 Hz; 195 x 235 x 105 mm; about 2 kg
Supplied withTest tube set of 5, spare light source, dust cover, instruction manual
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Water Analysis and Pharmacy Lab Exercises

Iron in water is a standard exercise. Students make iron standards from Ferrous Ammonium Sulphate, oxidise the iron to the ferric state and add Sodium Thiocyanate to give a blood-red colour. The standards are read on the 490 nm filter to give a calibration line for the water samples.

Pharmacy and chemistry students also plot an absorption curve with the 8-filter model. They read one coloured standard on every filter, blanked with Distilled Water, and plot optical density against wavelength. The peak shows the filter to use for that colour, a filter version of finding lambda max.

Frequently Asked Questions

Should I choose the 8-filter or the 5-filter model?
The 5-filter model keeps 450, 490, 540, 620 and 680 nm, which covers the common blue, green and red tests. The 8-filter model adds 400, 520 and 570 nm. Choose eight filters for yellow solutions near 400 nm or for plotting a fuller absorption curve.

What is the smallest sample I can read?
The minimum volume is 1 ml. Use the tubes from the set of five supplied, filled so the liquid covers the light path. Wipe them clean before each reading and keep scratched tubes out of the set.

How do optical density readings relate to percent transmittance?
Optical density is absorbance, and A = 2 − log10(%T). An OD of 1 means 10 %T passes through, and OD 2 would mean 1 %T. The display reads to 1.99 in steps of 0.01, so dilute very dark solutions first.

Why does the colorimeter have a shutter?
The built-in shutter closes the light path to the photocell between readings. A photocell kept under constant light ages faster, so the shutter lengthens its working life.

What does a negative reading mean?
A reading below zero means the blank absorbed more light than the sample. The blank may contain reagent colour that is missing from the sample, or its tube may be smeared or scratched. Set zero again on the same filter with a fresh blank in a clean tube, then read the sample again.

Other Colorimeters and Visible Spectrophotometers

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 6 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us