Jlab Export is a leading Visible Spectrophotometer Manufacturer,and suppliers in India

Four keys run this visible spectrophotometer. A Mode key steps between %T, absorbance, concentration and K factor, and the zero and blank are set automatically. It reads 350 to 1020 nm through a 1200/mm Czerny-Turner grating with a 6 nm bandwidth. Results show on a digital display, and samples sit in a 4-position rapid changer.

Specifications

MonochromatorCzerny-Turner CT grating, 1200/mm
Wavelength range350–1020 nm
Spectral bandwidth6 nm
Wavelength accuracy±3 nm, repeatability ≤1 nm
Measurement range0–199.0 %T, 0–1.999 A, 0–1999 C, K factor
Light source6 V, 10 W tungsten lamp
Stability±0.004 A/h at 500 nm after 1 hour preheat
Controls and display4 membrane keys with Mode key, automatic zero and blank, auto light door, digital display
Sample holder4-position rapid cuvette changer (test tube holder), 100 mm colorimetric stand
Interfaces and powerOptional Centronics printer, USB and RS232C; 220 V or 110 V AC, 50–60 Hz
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Phosphate in Water: Lab Exercises

Phosphate in pond or tap water is estimated in environmental chemistry classes by the molybdenum blue method. The reagent is based on Ammonium Molybdate, and phosphate turns it into a blue complex whose depth of colour follows the phosphate content. Students make up the phosphate standards in Volumetric Flasks, Class A Borosilicate Glass Plastic Stopper JLab.

The reagent blank goes in one position of the changer and three standards in the others, so the set is read without unloading. Small reagent volumes are added with a Single Channel Micro Pipette. The class can then compare a full calibration line with a K factor taken from one standard, and see where the two agree.

Frequently Asked Questions

How long should it warm up before readings?
The stability figure is given at 500 nm after a 1 hour preheat. For a long series of readings, switch on about an hour before the class. Readings taken straight after switching on drift more while the lamp settles.

How does the automatic blank setting work?
Move the blank into the beam and press the key, and the display is set to zero absorbance. Keep the blank in its own position in the changer, so you can return to it and set the blank again between samples.

When is the K factor mode worth using?
It saves time on routine batches. One standard gives the factor, and every sample then reads as concentration. For a teaching practical, plot the full line first, because the factor holds only where absorbance stays proportional to concentration.

What does the auto light door do?
It closes the light path when the sample compartment is opened. Room light does not reach the detector while you change samples, and the zero is not upset between readings.

Can it run on a 110 V supply?
Yes. It works on 220 V or 110 V AC at 50 to 60 Hz, so state the mains voltage of your lab when you send an enquiry.

Other Visible-Region Instruments

For a quote, use Add To Cart or send us a message through the contact page.