Volumetric Flasks, Class A Borosilicate Glass Plastic Stopper JLab Manufacturer,Supplier and Exporter in India
Product Code : EL-PVFAMC-1646
Jlab Export is a leading Volumetric Flasks, Class A Borosilicate Glass Plastic Stopper JLab Manufacturer,and suppliers in India
Class A is the tighter of the two volumetric classes, and this borosilicate flask is meant for standard solutions in analysis. It has a single mark on a narrow neck and a plastic stopper for mixing by inversion. Twelve sizes run from 1 ml to 2000 ml.
Specifications
| Class | A |
| Glass | Borosilicate |
| Stopper | Plastic |
| Capacities | 1, 2, 5, 10, 20, 25, 50, 100, 250, 500, 1000 and 2000 ml |
| Minimum order quantity | 50 units |
| Dispatch time | Usually 3–5 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Redox Titration Practicals for Class 12
For the Class 12 permanganate titration, students make a standard solution of Ferrous Ammonium Sulphate in this flask. A little dilute sulphuric acid goes in before making up, so the iron salt does not hydrolyse. Portions are then taken with a Bulb Pipettes, Class B Soda Glass, One Mark JLab into a conical flask.
Students titrate each portion with Potassium Permanganate from a Burette, Borosilicate Glass, with PTFE Stopcock. The permanganate is its own indicator, and the first pale pink that lasts marks the end point.
Frequently Asked Questions
When is Class A needed rather than Class B?
Choose Class A for standard solutions, quantitative analysis and results that will be compared between batches or labs. Class B has wider tolerances and suits routine teaching and rough dilutions.
Does the flask have to be dry before use?
No. It is filled to the mark with distilled water anyway, so a flask wet with distilled water is fine. It must be clean, and it should not be rinsed with the solution, because that would add extra solute.
Why add the last few millilitres with a dropper?
The neck is narrow, so a small volume raises the level quickly. Adding the final water drop by drop from a dropper or wash bottle lets you stop with the bottom of the meniscus on the mark.
Why should a warm solution cool before making up?
The flask is calibrated at room temperature. A warm solution takes up more space and shrinks as it cools, so a flask made up warm ends below the mark. Dissolving some solids warms or cools the water, so wait until it is at room temperature.
Other Volumetric Glassware
- Volumetric Flasks Class B Soda Glass Plastic Stopper JLab (Class B, soda glass)
- Graduated Pipettes, Class B Soda Glass JLab
- Glass Foot Measuring Cylinders Hexagonal Base Borosilicate Glass Class B JLab
For a quote, use Add To Cart or send us a message through the contact page.