Microprocessor Spectrophotometer Manufacturer,Supplier and Exporter in India
Product Code : EL-S-2168
Jlab Export is a leading Microprocessor Spectrophotometer Manufacturer,and suppliers in India
A tungsten halogen lamp alone lights this spectrophotometer, which works from 320 to 1100 nm, across the visible region and into the near infrared. It keeps 200 standard curves and 200 groups of data in memory, so a calibration made in one class can be recalled in the next. The curve shows on a 128 x 64 dot graphical LCD.
Specifications
| Wavelength range | 320–1100 nm, set automatically |
| Spectral bandwidth | 4 nm |
| Wavelength accuracy | ±1 nm, repeatability 0.3 nm |
| Photometric range | 0–200 %T, -0.3 to 3 A, Conc 0–9999 |
| Photometric accuracy | ±0.3 %T, repeatability 0.2 %T |
| Lamp and detector | Tungsten halogen lamp, silicon photodiode |
| Memory | 200 groups of data and 200 standard curves |
| Sample handling | 4-position rapid cuvette changer (test tube holder); 5–100 mm cuvettes with optional holders |
| Outputs and software | USB, parallel printer port, Basic PC software supplied |
| Supplied with | 4 glass cuvettes, mains lead, manual, dust cover |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Iron in Water: A Colour Reaction Practical
Estimating iron in a water sample is a standard analytical and environmental practical. Students prepare iron standards from Ferrous Ammonium Sulphate in Volumetric Flasks Class B Soda Glass Plastic Stopper JLab. The iron is turned into an orange-red complex with 1,10-phenanthroline, and each standard is read at the absorbance maximum of that colour. Reagent volumes are measured with Graduated Pipettes, Class B Soda Glass JLab.
The glass cuvettes supplied suit this work, since the colour is read in the visible region. Once saved, the calibration can be recalled by the next batch of students. They check it with one fresh standard and then read their own water samples against it.
Frequently Asked Questions
Can this model read samples in the UV?
No. It has only a tungsten halogen lamp and starts at 320 nm. UV work such as a drug assay needs a model with a deuterium lamp and quartz cuvettes, for example the Microprocessor UV-VIS Spectrophotometer.
How long can I rely on a stored standard curve?
Check it at the start of each session with one fresh standard. If that standard falls off the line, make a new curve. Do the same after changing a reagent batch or the lamp, since either can shift the colour or the readings.
What is the test tube holder for?
The 4-position rapid changer takes test tubes as well as cuvettes. Round tubes can give slightly different readings as they turn, so use matched tubes, mark each one and put it in the same way round every time.
What can the optional software add?
The Basic PC software comes with the instrument. The optional software adds wavelength scanning, multi-wavelength work and quantitative and kinetic modes, with the results handled on the computer through the USB port.
How do I know the lamp needs changing?
Readings that stay noisy after warm-up, a 100 %T setting that will not hold, or a lamp that has darkened all point to a worn lamp. Replace it with a tungsten halogen lamp of the same type and let it warm up before use.
Other Visible-Range Spectrophotometers
- Visible Spectrophotometer (LED display with K factor)
- Digital Spectrophotometer (holographic grating, test tube holder)
- Microprocessor Visible Spectrophotometer JLab
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 6 November 2026