• +91-85699-09696

Bubble Solution For Leak Detection Manufacturer,Supplier and Exporter in India

Image Not Found .

Product Code : EL-RACLE-12779
Jlab Export is a leading Bubble Solution For Leak Detection Manufacturer,and suppliers in India

Sprayed on a joint under pressure, this solution shows a leak as bubbles that grow at the point where gas escapes. It comes in a spray bottle, forms large elastic bubbles that last, and is meant for pinpointing small leaks on surfaces at 5–50 °C.

Specifications

ApplicatorSpray bottle
GasesMost gases, including air, oxygen and refrigerants
BubblesLarge, long-lasting, well-defined elastic bubbles that hold up under pressure
Surface temperature5–50 °C
Main usePinpointing small leaks
Minimum order quantity10 units
Dispatch timeUsually 3–5 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Leak Test Practicals with Bubbles

Bubble testing is usually the first leak check trainees learn. They pressurise a brazed test piece or a trainer with dry nitrogen from one of the Nitrogen Gas Cylinders. The pressure is set with the Nitrogen Pressure Test Kit. Then they spray every joint and watch for bubbles that keep growing.

On a charged system the same solution confirms a leak found another way. Students locate the leak area with the Infrared Refrigerant Leak Detector, then spray the joints there to find the exact point. Teachers can show how a small leak builds a slow cluster of fine bubbles, while a large one blows the film away.

Frequently Asked Questions

How do I use the bubble solution?
Spray it on the joint, fitting or weld while the part is under pressure, and watch for a minute or two. Growing bubbles or foam mark the leak. Wipe the area dry after the test.

What surface temperature does it work at?
Use it on surfaces between 5 and 50 °C. On a very cold suction line or a hot discharge line, let the pipe come within that range first, or the film will not form good bubbles.

Why do no bubbles show on a large leak?
A fast leak can blow the film away before bubbles form, and wind does the same outdoors. Find a large leak first by sound or by a falling gauge, then use the solution to pin down small ones. Pressurise with dry nitrogen, never oxygen or compressed air.

Why must the system be under pressure for the test?
Bubbles only form where gas is pushing out through the leak. In a system at low pressure or under vacuum nothing escapes, so pressurise it with nitrogen, or run it to raise the pressure on the side under test.

Other Leak-Detection Tools

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 5 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us