• +91-85699-09696

Condensate Removal Pump Manufacturer,Supplier and Exporter in India

Image Not Found .

Product Code : EL-RACLE-12833
Jlab Export is a leading Condensate Removal Pump Manufacturer,and suppliers in India

A condensate removal pump lifts the water that collects in an air conditioner’s drain pan and pushes it to a drain that gravity cannot reach. This one is made for domestic air conditioning systems. It draws 10 W from a 220–240 V, 50 Hz supply, moves up to 30 l/h and has a detection device, an LED indicator and a low-noise design.

Specifications

ForDomestic air conditioning systems
Power supply220–240 V, 50 Hz
Power10 W
Maximum flow rate30 l/h
FeaturesDetection device, LED indicator, low noise
Minimum order quantity10 units
Dispatch timeUsually 4–6 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Lab Exercises: Setting Up the Pump

Students mount the pump below the indoor unit of a Split Air-Conditioner and lead the unit’s drain hose into the pump inlet. From the outlet they run Transparent Vinyl Tube For Condensate Pumps up and across to the drain point, keeping it free of kinks and dips.

To test the set-up, they pour water slowly into the drain pan and watch the pump start, then stop as the level falls. Collecting the outflow in a Measuring Cylinder while a Digital Stopwatch runs gives the actual flow. Students work it out in litres per hour and compare it with the 30 l/h maximum at different lift heights.

Frequently Asked Questions

When does an air conditioner need a condensate pump?
When the indoor unit sits below the drain, or the drain run is too long or too flat for water to flow by gravity. Common cases are units on inside walls, in basements or far from an outside wall.

How does the pump know when to run?
Its detection device senses water arriving from the drain pan and switches the pump on, then off again once the water has been cleared. The LED indicator gives a quick visual check on the pump.

Is 30 l/h enough for a home split AC?
For a typical home unit, yes. A domestic split AC usually produces a few litres of condensate per hour even in humid weather, well below the pump’s 30 l/h maximum. Flow falls as the lift height rises, so keep the vertical run short.

How do I test the pump after fitting it?
Pour clean water slowly into the drain pan and watch the pump start, clear the water and stop again. Check that water comes out at the far end of the tube and that no joint drips. Repeat the test before each cooling season.

Other Split AC Drain and Service Parts

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 5 November 2026


   