Compressor Manufacturer,Supplier and Exporter in India
Product Code : EL-RACLE-12826
Jlab Export is a leading Compressor Manufacturer,and suppliers in India
This 1/3 HP compressor suits domestic refrigeration systems charged with R-134a, and its motor starts through a PTC starting relay. In an RAC training workshop it is the unit students identify, test on the bench and then braze into a refrigerator circuit.
Specifications
| Application | Domestic refrigeration |
| Motor rating | 1/3 HP |
| Refrigerant | R-134a |
| Starting relay | PTC |
| Minimum order quantity | 10 units |
| Dispatch time | Usually 4–6 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Workshop Practice for RAC Trainees
The first job is finding the common, start and run pins. Students read the resistance across each pair of pins with a Digital Multimeter and write down the three values. They then check that no winding leaks to the shell, testing from each pin to bare metal on the body with an Insulation Tester.
Next, the compressor is wired on the bench with its PTC relay and a flat-type Compressor Protection Overload. Once it runs, trainees can compare it with the compressor of the Basic Refrigeration Training Unit, which is also a 1/3 HP unit on R-134a. The last step is brazing it into a practice circuit, then evacuating and charging the system.
Frequently Asked Questions
How do I identify the common, start and run terminals?
Measure the resistance across all three pairs of pins. The highest reading is between start and run, so the pin left out of that pair is common. From common, the start winding reads higher than the run winding, and the two smaller readings add up to the highest.
How do I test the PTC relay?
Unplug the supply, pull the relay off the compressor pins and let it cool to room temperature. Measure across the sockets that fit the start and run pins. A low reading is normal, while an open circuit or a cracked, rattling case means it has failed.
Should the relay and overload be changed with the compressor?
Yes, as a rule. A relay or overload that caused the failure, or was damaged by it, can stop the new compressor from starting or let it overheat. Fit the start parts matched to this compressor and keep the old ones out of the spares box.
How should a new compressor be stored before fitting?
Keep it upright with its pipe stubs sealed until brazing. The oil used with R-134a takes up moisture from the air, so leave the stubs open for as short a time as possible. Fit a new filter drier with every compressor change.
Other Parts for Domestic Refrigeration Circuits
- Compressor (1/2 HP, R-134a)
- Compressor Start Relay (four-terminal current relay)
- Filter Drier
- Capillary Tube
For a quote, use Add To Cart or send us a message through the contact page.