This contamination detector kit is used in refrigeration and AC service to check for three problems: acidity, moisture and oil. It holds one metering device with three test sets for each, which is enough for three checks of every kind.

What the Kit Contains

Metering device1
Acidity test sets3
Moisture detection sets3
Oil detection sets3
Minimum order quantity10 units
Dispatch timeUsually 4–6 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Lab Exercises on System Contamination

After a compressor burnout or a long open repair, trainees test the system before they choose a clean-up method. The acidity sets show whether acid has formed. The class can compare that result with an oil sample checked on the Acid Test Kit For All Refrigeration Oils. A moisture result helps them judge whether a new Filter Drier and a deep evacuation are needed.

The oil detection sets serve a recovery lesson, since recovered refrigerant that is to be reused should carry as little oil as possible. Students test a sample after it has passed through the Refrigerant Recycling Machine and record the result.

Frequently Asked Questions

What does the kit test for?
Acidity, moisture and oil. It contains one metering device and three sets for each test, so a technician can make three checks of each kind before new sets are needed.

When should a system be checked for contamination?
Check after a compressor burnout or when a system has been open to air for a long time. Check also before recovered refrigerant is reused, and when a fault keeps coming back after repair.

Why does moisture matter in a refrigeration system?
Water can freeze at the expansion device and block the flow. It also reacts with the refrigerant and oil to form acids, which attack motor windings and metal parts over time.

How do I keep the sample from giving a false result?
Take the sample through clean, dry hoses and test it straight away. Air or moisture picked up on the way can make a dry system look wet. Use a fresh test set with the metering device for each check, and keep the unused sets sealed and dry.