• +91-85699-09696

Compressor Manufacturer,Supplier and Exporter in India

Image Not Found .

Product Code : EL-RACLE-12821
Jlab Export is a leading Compressor Manufacturer,and suppliers in India

Isobutane, sold as refrigerant R-600a, is the gas this 1/8 hp compressor is built to pump. It is meant for domestic refrigeration and starts through a PTC relay. Still air around the shell keeps it cool (cooling type S), so no fan has to blow over it.

Specifications

ApplicationDomestic refrigeration
Motor power1/8 hp
RefrigerantR-600a
Starting relayPTC
Cooling typeS (static)
Minimum order quantity10 units
Dispatch timeUsually 4–6 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Hydrocarbon Compressor Practicals for Students

R-600a is a flammable hydrocarbon, so a practical on this compressor starts with the safety set-up. The bench is well ventilated, with no flame or spark nearby. Students recover any old charge with the Combustible Gas Recovery Machine, which handles flammable refrigerants such as R-600a.

After purging with nitrogen and brazing in the new compressor and a fresh filter drier, they evacuate the circuit. The charge is then weighed in on the High Precision Charging Scale, which reads to 1 g. During the first run, the Hydrocarbon Manifold Gauges with their R-600a scale show suction and discharge pressures.

Frequently Asked Questions

What does 1/8 hp tell me?
It is the motor power, one of the smallest sizes used in domestic refrigeration, for a small cooling load such as a compact refrigerator. Always match the horse power and the refrigerant shown on the old compressor label.

What precautions apply to an R-600a compressor?
R-600a is isobutane, a flammable gas. Work in a ventilated area with no flame or spark nearby, use tools made for hydrocarbon refrigerants and never braze on a circuit that still holds gas. Charge by weight, because a domestic system holds only a small charge.

What does the PTC starting relay do?
A PTC relay holds a ceramic part with low resistance when cold, so current flows through the start winding at switch-on. As the current heats it, its resistance rises sharply and the start winding drops out, leaving the run winding in circuit.

What does cooling type S mean?
S stands for static cooling. The natural movement of air around the shell is enough to cool the compressor, so it needs no fan. It does need free air space in the machine compartment.

Other Compressors, Parts and Refrigerant

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 5 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us