Combustible Gas Recovery Machine Manufacturer,Supplier and Exporter in India
Product Code : EL-RACLE-12762
Jlab Export is a leading Combustible Gas Recovery Machine Manufacturer,and suppliers in India
Hydrocarbon refrigerants such as R600a and R290 are flammable, and this recovery machine is made to take them out of a system as well as the usual types. It recovers A2L and A3 refrigerants along with CFC, HCFC and HFC refrigerants. Its electric wiring and switches are sealed, and it runs on 220–240 V, 50 Hz.
Specifications
| Refrigerants | CFC, HCFC and HFC, plus A2L and A3 flammable types such as R600a and R290 |
| Electrical parts | Sealed wiring and switches |
| Power supply | 220–240 V, 50 Hz |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Practicals on Hydrocarbon Refrigeration Systems
Many domestic refrigerators now run on R600a, and many lab trainers on R290. Before such a unit is repaired, students recover the charge through the Hydrocarbon Manifold Gauges, whose scales read R-600, R-600a and R-290. The gas goes into a recovery cylinder kept for that refrigerant. The work is done in a ventilated area with no flames, and the bench is checked first with a Combustible Gas Detector.
After the repair and a leak test, students recharge by weight. Hydrocarbon charges are small, so they weigh R-600a Refrigerant from a can into the system on the High Precision Charging Scale. That scale is made for R600a and R290 and reads to 1 g.
Frequently Asked Questions
What do A2L and A3 mean?
They are refrigerant safety classes. The letter A means lower toxicity. Class 2L covers mildly flammable refrigerants, and class 3 covers highly flammable ones such as R290 and R600a.
Why are the wiring and switches sealed?
Switch and relay contacts can spark as they open and close. Sealing them keeps flammable gas away from those parts. The work area still needs good ventilation and no open flames or other sources of ignition.
Can it also recover ordinary refrigerants?
Yes. It handles CFC, HCFC and HFC refrigerants as well, so one machine can serve a lab with several kinds of trainer. Keep a separate recovery cylinder for each refrigerant and never mix them.
How is it different from the standard recovery machine?
The Refrigerant Recovery Machine is rated for Categories III, IV and V, which do not include hydrocarbons. This machine adds A2L and A3 refrigerants and has sealed wiring and switches, so it is the one to use on hydrocarbon systems.
Other Items for Hydrocarbon System Repair
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 5 November 2026