Combustible Gas Detector Manufacturer,Supplier and Exporter in India
Product Code : EL-RACLE-12766
Jlab Export is a leading Combustible Gas Detector Manufacturer,and suppliers in India
This handheld unit detects leaks of propane, methane, butane, industrial solvents and other hydrocarbon or combustible gases. It warms up in 25 seconds and runs for 20 hours on its batteries. It has a 17 in (43.17 cm) probe on a 10.5 in (26.67 cm) body, and weighs 16 oz (0.45 kg).
Specifications
| Gases detected | Hydrocarbons and other combustible gases, including propane, methane, butane and industrial solvents |
| Warm-up time | 25 seconds |
| Battery life | 20 hours continuous |
| Sensor life | 500 hours |
| Probe length | 17 in (43.17 cm) |
| Body length | 10.5 in (26.67 cm) |
| Weight | 16 oz (0.45 kg) |
| Operating temperature | 0–43 °C (32–110 °F) |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Gas Leak Practicals in the Workshop
On a hydrocarbon refrigeration trainer, students check every brazed joint and flare nut after a repair, with the system charged through the Hydrocarbon Manifold Gauges. Propane and butane are heavier than air, so they move the probe slowly under each joint and near the floor around the unit. Methane is lighter, so it is checked above the joint.
In the brazing area, students check the cylinder valve, the regulator and the joints of the LPG Hose before a torch is lit. A leak found by the detector is then pinned down with Bubble Solution For Leak Detection.
Frequently Asked Questions
Can it find refrigerant leaks?
It finds leaks of hydrocarbon refrigerants such as propane and isobutane, because they are combustible gases. For HFC, HCFC and HFO refrigerants use the Infrared Refrigerant Leak Detector, which is made for them.
Why does it need 25 seconds to warm up?
The sensor needs time to reach a steady state. Switch it on in clean air and wait out the warm-up, so the detector starts from a clean baseline and does not read normal air as gas.
How long do the sensor and batteries last?
The sensor is rated for 500 hours of use, and the batteries give 20 hours of continuous running. Switch the detector off between checks to save both, and carry spare batteries on long jobs.
Can it check LPG and natural gas lines?
Yes. It detects propane and butane, the gases in LPG, and methane, the main gas in natural gas. Use it to locate a leak, then confirm the exact point with bubble solution before any repair.
Other Items for Hydrocarbon Systems
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 5 November 2026