Acid Test Kit For All Refrigeration Oils Manufacturer,Supplier and Exporter in India

Image Not Found .

Product Code : EL-RACLE-12778
Jlab Export is a leading Acid Test Kit For All Refrigeration Oils Manufacturer,and suppliers in India

Acid in compressor oil usually follows a motor burnout or moisture in the system, and it keeps attacking windings and metal parts until it is removed. This kit tests a sample of any refrigeration oil for acid and shows the result by a colour change.

Specifications

Oils testedAll refrigeration oils
DetectsAcid formation in the oil
Result shown byColour change
Minimum order quantity10 units
Dispatch timeUsually 4–6 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Oil Acid Test Practicals After a Burnout

A standard RAC practical follows a compressor burnout. Trainees take an oil sample from the failed compressor, test it with the kit and record the colour. After the clean-up with the Flush Machine and a new Filter Drier, they run the system and test the oil again to see whether the acid has gone.

Students can also compare fresh Mineral Oil from a sealed container with oil drained from a long-used trainer. The contrast shows how the state of the oil reflects what has happened inside the system.

Frequently Asked Questions

Which oils can it test?
It is made for all refrigeration oils, so one kit covers the mineral, alkyl-benzene, POE and PAG oils found in refrigeration and AC compressors.

How do I read the result?
A colour change shows that acid has formed in the oil sample. If the colour does not change, no acid was found in that sample. Test again after any clean-up, since acid can return while burnt residue remains.

Can acid form in a system that never had a burnout?
Yes. Oil breaks down slowly with heat, moisture and air over years of running, so acid can build up in an ageing system that seems to work normally. Testing at routine services shows the change early, before the acid attacks the motor windings.

What should I do if acid is found?
Drain and replace the oil, change the drier for a burnout-type one and, after a severe burnout, flush the lines. Run the system, then test again and repeat the clean-up until the result shows no acid.

How is an oil sample taken?
Draw it from the compressor drain or an oil sampling point into a clean container and test it straight away. Wear gloves and eye protection, because oil from a burnt-out compressor can be acidic.

Other Oil Checks and Oil Service Items

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 5 November 2026


   