Mufflers Manufacturer,Supplier and Exporter in India
Product Code : EL-RACLE-12845
Jlab Export is a leading Mufflers Manufacturer,and suppliers in India
A discharge muffler sits in the hot gas line between the compressor and the condenser. Gas leaves a reciprocating compressor in pulses, one per stroke, and the chambers inside a muffler smooth those pulses out. Less noise and shaking then reach the pipework. This muffler has a brass body with 1/2 in flare connections.
Specifications
| Connection | 1/2 in flare |
| Material | Brass |
| Colour | Brass tone |
| Minimum order quantity | 10 units |
| Dispatch time | Usually 4–6 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Workshop Practice with Flare-Connected Mufflers
The muffler is a good part for practising flare joints. Students cut copper pipe square, deburr it, slip on the flare nut and form a 1/2 in flare with the 45 Degree Flaring And Swaging Tool. They fit the muffler in a discharge line, tighten the nuts and check each joint with Bubble Solution For Leak Detection under nitrogen pressure.
To show why the part is there, the teacher opens up the Reciprocating Compressor (Actual Cut Section). It shows the piston and the discharge valve that send out one pulse of gas per stroke. On a running rig, students then compare the line noise before and after the muffler with a Digital Sound Level Meter.
Frequently Asked Questions
Which way should a discharge muffler be installed?
In the discharge line, close to the compressor. Mount it vertically with the gas flowing downwards, or horizontally, so oil carried by the hot gas drains through it. Mounted with the flow going upwards, it can trap oil.
Why does a refrigeration system need a muffler?
A reciprocating compressor pushes gas out in pulses. Those pulses make the discharge line ring and shake, and the noise spreads through the pipework into the cabinet. The muffler damps the pulses before they reach the condenser.
How do I make a leak-free flare joint on it?
Cut the pipe square, deburr it and put the nut on before flaring. Form a 45 degree flare and put a drop of refrigeration oil on its face. Tighten the nut firmly without overdoing it, since too much force can split the flare. Then leak test the joint.
Is a muffler the same as a vibration damper?
No. Vibration Dampers are flexible and stop mechanical shaking travelling along the pipe. A muffler is a rigid chamber that damps the pressure pulses in the gas itself. Many systems use both on the discharge side.
Other Parts for the Hot Gas Line
- Solenoid Valves (gas side)
- Four Way Valve (heat pump reversing valve)
For a quote, use Add To Cart or send us a message through the contact page.