Built for R-134a, this compressor has a 1/6 hp motor for domestic refrigeration. It shares its motor size with the isobutane model in the range, but not its refrigerant, oil or working pressures. A PTC relay handles starting, and with static cooling (type S) no fan is needed over the shell.

Specifications

RefrigerantR-134a
Motor power1/6 hp
ApplicationDomestic refrigeration
Starting relayPTC
Cooling typeS (static)
Minimum order quantity10 units
Dispatch timeUsually 4–6 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Compressor Replacement Practicals

A full compressor change on an R-134a system is a core practical in refrigeration training. Students recover the charge with the Refrigerant Recovery Machine and cut out the old compressor. They braze in the new one under a slow nitrogen flow set on the Nitrogen Flow Regulator Meter For Brazing, which keeps scale from forming inside the pipes.

After fitting a new drier and pulling a vacuum, they charge the system with R-134a Refrigerant. Suction and discharge pressures are followed on the Manifold Gauges For Refrigeration Systems, whose scale covers R-134a.

Frequently Asked Questions

Which oil does an R-134a compressor use?
R-134a compressors are filled with a polyolester (POE) oil, because the mineral oil used with older refrigerants does not mix with R-134a. POE oil takes up moisture quickly, so keep the stubs sealed until the compressor is brazed in.

How is it different from the 1/6 hp isobutane compressor?
The motor power is the same, but the refrigerant is not. This model is for R-134a, a non-flammable HFC, while the other is for isobutane. Their pressures, oils and charges differ, so one cannot replace the other.

Why fit a new filter drier with the compressor?
Opening the system lets in air and moisture, and the old drier may hold acid or debris from the failed compressor. A new drier protects the replacement, which matters with moisture-sensitive POE oil.

How is R-134a charged into the system?
After a deep vacuum, charge by weight to the amount on the appliance label, or by pressure and temperature readings on a manifold. R-134a is a single refrigerant, not a blend, so it can be charged as vapour on the low side.