Cryobath Manufacturer,Supplier and Exporter in India
Product Code : EL-CB-2323
Jlab Export is a leading Cryobath Manufacturer,and suppliers in India
A cryobath holds a tank of liquid at a set temperature below room level, using its own compressor to cool and an immersion heater to trim. Here the inner pot is one-piece stainless steel, argon welded, inside a double wall with 2 in of insulation. A side mounted pump moves the liquid at 15 L/min in place of a stirrer, and a PID controller shows set and process values.
Specifications
| Inner pot | One-piece stainless steel, argon welded |
| Body | Double walled, 2 in thick insulation |
| Compressor | CFC-free, hermetically sealed, with time delay |
| Refrigerant | R 134 A |
| Circulation | Side mounted pump, 15 L/min, single phase, 230 V |
| Heater | Stainless steel tubular, water immersion type, at the bottom |
| Controller | Microprocessor based, auto tuned PID, dual display of set and process value |
| Alarms | Audio-visual, temperature overshoot and undershoot |
| Compressor ON delay | 2 min timer |
| Lid | Top mounted, removable |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Lab Exercises for Students and Technicians
Biomedical-engineering students can watch the protection logic at work. They switch the bath on and time the compressor start with a Digital Stop Watch, which should match the 2 min ON delay. With the bath at its set point, they raise the set value sharply to bring on the undershoot alarm. Lowering it then sets off the overshoot alarm.
A second exercise checks the controller against an independent probe. Students place a Calibratable Digital Thermometer near the pump outlet and again at the far side of the pot. They log both readings beside the process value every few minutes to see how evenly the pump spreads the cold. The optional data logger can record the same run.
Frequently Asked Questions
What do the overshoot and undershoot alarms tell me?
An overshoot alarm means the liquid has gone warmer than the set band, for example when the heater stays on too long. An undershoot alarm means it has gone colder. Either one is a sign to check the settings and the load before use continues.
What should I check if the bath will not pull down to its setting?
Make sure the lid is on and the load placed in the bath was not too warm. Keep the condenser vents clear and the room cool. Check that the heater is not running against the compressor. A bath that still cannot reach its setting needs a refrigeration service check.
Why is the inner pot made in one piece?
A single argon welded stainless steel pot has no seams along the sides and floor that could open with repeated cooling and warming. That keeps the bath liquid inside the pot and away from the insulation.
Why should the controller settings be written down?
Record the set value and the alarm settings once the bath is set up for its job. If they are changed by mistake or after a fault, the record lets you restore them and shows whether anything has drifted since.
Other Temperature-Controlled Equipment
For a quote, use Add To Cart or send us a message through the contact page.