Electromatic  O.T. Table

Product Code : EL-OTF-2029
Jlab Export is a leading Electromatic O.T. Table Manufacturer,and suppliers in India

This operation theatre table is driven by electric actuators, and every position is set from a remote control. The actuators run at a steady speed with little noise. The top and the base are stainless steel, the table works on a 24 V DC supply, and a battery backup of 2–3 hours can be added.

Specifications

DriveElectric actuators, set by remote control
Top and baseStainless steel
Top size1930 x 553 mm
Height adjustment762–1012 mm
Trendelenburg / reverse30° / 25°
Lateral tilt20° / 20°
Kidney elevator150 mm
Back rest, head rest (up / down)80° / 25°, 20° / 60°
Leg rest (up / down)15° / 90°
Power supply24 V DC, battery backup of 2–3 hours optional
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Positions and the Orthopaedic Attachment

From the remote, the table rises and lowers, tilts head-down and head-up, tilts to either side, flexes and reflexes, and folds into a chair position. The head and leg sections are interchangeable. An orthopaedic attachment with pelvis, hip and leg supports comes with the table, and the eccentric column leaves room for a C-arm to reach round the limbs.

Lab Exercises for Nursing and BME Students

In a nursing skills lab, students first name each section and control. They then lay a Multi Functional Nursing Manikin on the top and move it into the head-down, head-up and chair positions from the remote. Biomedical-engineering students run a pre-use check. They take each movement through its full travel, test the end stops and listen to the column for noise or drift. Where the battery backup is fitted, they also try it with the mains off.

In a theatre layout exercise, the class sets the table under a Ceiling Shadowless Surgical Operation Theatre Light. Students place a Mayo Instrument Table over the foot end and park an Instrument Trolley beside it. They then check that the path for a C-arm past the column stays clear.

Frequently Asked Questions

One movement has stopped but the others still work. What should be checked?
Check that the remote cable and plug are fully seated and that the movement is not at its end stop. If the rest run from the same remote, the fault is likely in that section’s actuator or wiring. A trained technician should test it.

Can the table be moved during a mains power cut?
Only when the optional battery backup is fitted, which runs the table for about 2–3 hours. Without it, the actuators need the 24 V DC supply. Keep the battery charged between lists and try it during the pre-use check.

Can a C-arm be used with this table?
Yes, for work on the hips and limbs. The eccentric column and the orthopaedic attachment are laid out so that a C-arm can be brought round the legs during the operation. Plan the room so that the arm has a clear path past the base.

What does it mean if the table drifts or grinds while moving?
Take it out of use and report it. The actuators normally run at a steady speed with little noise. Drift, grinding or a jerky movement points to a worn actuator, a loose mounting or a control fault.

What does the orthopaedic attachment include?
It has a pelvis support with hip and leg supports, so the limbs can be held and positioned for orthopaedic work. Fit and adjust it with the table level and empty, and check each clamp before a patient is moved onto it.