Gear Matic Hydraulic O.T. Table Manufacturer,Supplier and Exporter in India
Product Code : EL-OTF-2030
Jlab Export is a leading Gear Matic Hydraulic O.T. Table Manufacturer,and suppliers in India
Here the theatre staff do the work by hand and foot. Stepping down on the pedal pumps the top up, and the five sections are set by a mechanical drive, so the table needs no mains supply. The top segments let X-rays through, and the eccentric base leaves the floor clear for a C-arm to move round.
Specifications
| Height drive | Hydraulic, raised by stepping on a foot pedal |
| Section drive | Manual, by mechanical drive |
| Table top | Five sections, top segments translucent to X-rays |
| Base and column | Eccentric base, covered with stainless steel |
| Top size | 1905 x 553 mm |
| Height adjustment | 787–1042 mm |
| Trendelenburg / reverse | 30° / 25° |
| Lateral tilt | 20° / 20° |
| Kidney elevator | 150 mm |
| Back, leg and head rests (up / down) | 80° / 25°, 15° / 90°, 20° / 60° |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
How the Gear and Pedal Drives Work
The foot pedal works a hydraulic pump in the column, and each stroke lifts the top a little. The back, leg and head rests, the tilts and the kidney elevator are moved through the mechanical drive. The leg and head sections are interchangeable, and the base and column are covered in stainless steel for wiping down.
Practicals for Nursing and BME Students
Biomedical-engineering students can check the hydraulics as a service exercise. They pump the top from its lowest to its highest point and read both heights with a Steel Tape (Measuring). A Digital Stopwatch times the climb. Leaving the top raised for half an hour and measuring again shows whether it sinks.
Nursing students practise preparing the table for a list. They test each section, set the kidney elevator and lay a Basic Combination Nursing Manikin on the top. A Foot Step beside the table gives a shorter student a safe reach over the manikin.
Frequently Asked Questions
What is the kidney elevator for?
It raises a bridge under the middle of the top by up to 150 mm. With the patient on their side, this arches the body and opens the space between the ribs and the hip. Raise it slowly, and only as far as the surgical team asks.
What should a hospital maintenance team check on a hydraulic table?
Look under the column for oil, and check that the top holds its height without creeping down. Turn every gear drive through its range and listen for binding. Check the stainless steel covers for loose fixings and keep a record of each check.
Which part of the table can be X-rayed through?
The top segments are translucent to X-rays, so a C-arm can image the patient through the top. Keep clamps, rails and other metal accessories out of the beam, and check the set-up with the radiographer before the list starts.
How should a new table be tried before it goes into use?
Run every movement through its full range and compare it with the table sheet: height 787–1042 mm, head-down tilt up to 30° and side tilt 20° each way. Note how many pedal strokes the full climb takes and how easily the gears turn.
Why are the head and leg sections interchangeable?
Swapping them lets the team change which end of the top carries the longer or shorter section to suit the patient and the operation. Swap them with the table level and empty, and check both locks before use.
Other Theatre Tables and Furniture
- Electromatic O.T. Table (electric actuators)
- C Arm O.T. Table
- Super Deluxe O.T. Table
- Surgeons Stool
For a quote, use Add To Cart or send us a message through the contact page.