Forced Air Gas Burner Training Panel Manufacturer,Supplier and Exporter in India
Product Code : EL-ELA-5445
Jlab Export is a leading Forced Air Gas Burner Training Panel Manufacturer,and suppliers in India
Forced Air Gas Burner Training Panel (code EL-ELA-5445) is a gas-engineering trainer that simulates the operation of a forced-air gas burner using air instead of gas, so it can be used in ordinary training rooms without hazard. A diaphragm pump supplies the air, single-tube manometers show the key operating pressures, a flame safeguard monitors the burner and a flickering light shows when it is “firing”. It is made by Jain Laboratory Instruments Pvt Ltd (JLab) at its works in Ambala, India.
Specifications
| Parameter | Detail |
|---|---|
| Type | Training panel simulating the operation of a forced-air gas burner |
| Operating medium | Air — hazard-free burner operation, suitable for training rooms |
| Pressure generation | Diaphragm pump, pumping medium air |
| Gas control elements | Combined into one compact fitting |
| Pressure display | Most important operating pressures on single-tube manometers |
| Burner operation indicator | Flickering light |
| Burner monitoring | Flame safeguard |
| Load setting | Practical nominal load adjustment |
| Gas burner rating class | 13 kW to 28 kW |
| Gas pressure controller admission pressure | 0.4 bar |
| Gas pressure controller outlet pressure | 0.04 bar |
| Diaphragm pump power consumption | 70 W |
| Maximum flow rate | 70 L/min at 230 mbar |
| Quality check | Each training panel is visually inspected before dispatch |
| Pack quantity | Each (sold individually) |
| Minimum order quantity | 10 units |
| Dispatch time | Usually 7–10 working days |
| Product code | EL-ELA-5445 |
| Manufacturer | Jain Laboratory Instruments Pvt Ltd (JLab) — OEM |
| Country of origin | India (made in Ambala, Haryana) |
How Does It Compare with the Demo Unit Gas Burner?
| Trainer | Medium | Burner size | Listed training features |
|---|---|---|---|
| This panel (EL-ELA-5445) | Air from a diaphragm pump — no gas burnt | Rating class 13–28 kW (simulated) | Single-tube manometers, flame safeguard, flickering-light indicator, nominal load adjustment, compact gas control fitting |
| Demo Unit Gas Burner | Fully automatic forced-air gas burner for natural gas | 15–45 kW | Simulation of all burner operating states, fault switches in a lockable box, PLC, real system components such as flame safeguard, ignition transformer and gas solenoid valves |
Choose this panel when trainees should learn burner pressures, load setting and flame monitoring with no gas on site; the Demo Unit Gas Burner suits fault-finding courses built around a natural-gas burner and its electrical controls.
What Is the Forced Air Gas Burner Training Panel Used For?
In a forced-air (forced-draught) burner a fan delivers the combustion air, while the gas train in front of it controls the gas: the pressure controller brings the higher admission pressure down to a steady outlet pressure, here from 0.4 bar to 0.04 bar, and the flame safeguard keeps the gas valves open only while a flame is proved. On this panel the same elements are combined in one compact fitting and fed with air from the diaphragm pump, so trainees can watch the pressures on the single-tube manometers, follow the burner sequence through the flickering light and the flame safeguard, and practise setting the nominal load of a burner in the 13–28 kW class.
It suits gas fitter, plumber and heating-service courses in ITIs and TVET centres, polytechnic diplomas in mechanical or building services engineering, and in-house training at gas utilities, because no gas supply, flue or ventilation for combustion products is needed while the panel runs.
What to Specify When Ordering
- Quantity — the minimum order is 10 units; a workshop often plans one panel for each small group.
- Electrical supply — the voltage and plug type in your training room, for the diaphragm pump.
- Companion trainers — gas supply, burner and gas heater trainers listed below can go in the same enquiry.
Frequently Asked Questions
Does the training panel burn real gas?
No. The burner function is simulated with air from a built-in diaphragm pump, which is why the panel can be used in training rooms without hazard.
What burner size does it represent?
Gas burners of rating class 13 kW to 28 kW. The gas pressure controller works with an admission pressure of 0.4 bar and an outlet pressure of 0.04 bar.
What can trainees practise on it?
Reading the main operating pressures on the single-tube manometers, practical nominal load adjustment, following burner operation through the flickering light, and seeing how the flame safeguard monitors the burner.
What does it need to run?
A mains power supply for the diaphragm pump, whose power consumption is 70 W; the pump delivers up to 70 L/min of air at 230 mbar. No gas connection is used.
How is it different from the Demo Unit Gas Burner?
The Demo Unit Gas Burner is listed as a fully automatic forced-air burner for natural gas, 15–45 kW, with fault switches and a PLC. This panel simulates a burner with air and concentrates on pressures, load adjustment and flame monitoring.
What should an export enquiry include?
Quantity, destination country and port or city, delivery terms such as FOB or CIF, the electrical supply at site, packing or labelling needs, and any tender reference.
Who manufactures the panel?
Jain Laboratory Instruments Pvt Ltd, trading as JLab, at its works in Ambala, Haryana, India.
OEM Manufacturer
JLab is the trading name of Jain Laboratory Instruments Pvt Ltd, a manufacturer of technical training equipment and lab apparatus in India, incorporated in 2017 and based on Hargolal Road, Ambala, Haryana. The burner training panel is assembled in JLab’s own works, not sourced from a trader, so training centres, colleges, dealers and importers buy direct from the maker, every panel is visually inspected before dispatch, and repeat orders and spares come from the same works. JLab exports worldwide and ships to buyers in every region — for example Costa Rica in Central America and the Caribbean, Georgia in Eastern Europe, Turkey in the Middle East, Chile in South America and Finland in Northern Europe. Tender buyers can refer to the JLab lab tenders page.
Related Gas Training Equipment
- Demo Unit Gas Burner — a natural-gas forced-air burner model with fault simulation.
- Domestic Gas Supply Training Panel — exercises on gas pipes, gas meters, pressure controllers and leak finding.
- Instantaneous Gas Heater — an instantaneous heater trainer also operated with air, with PLC fault simulation.
- Training Panel Function of Gas Heater — a propane-fired combination water heater on a panel.
- Exhaust Gas Analyser — for analysing the gases in an exhaust once trainees move on to real burners.
Browse the Educational Laboratory Apparatus range or all Laboratory Apparatus.
Request a Quote
JLab quotes directly as the manufacturer. Use the Add To Cart enquiry button on this page, or send the number of panels (minimum 10 units), your electrical supply and the delivery location through the contact page.
Last updated: 9 October 2026